Dispenser calibration
The dispensers need to be calibrated to
ensure the dispenser pumps supply the
correct amount of liquid agent.
Supervisor level ~ Settings
Dispenser calibration
Dispensing throughput
After selecting "Dispenser calibration":
Settings ~ Dispenser calibration
Dispenser pump 1
Dispenser pump 2
Selection choice: 1 to 13
After selecting a dispenser pump the
following message will appear in the display:
Dispenser calibration ~ Dispenser pump 1
V: 100ml
t: 0s
The amount to dispense can be set between
0 and 999 ml in 1 ml increments.
After selecting the parameters you want
press the multi-function dial to activate the
dispenser pump.
Dispenser calibration ~ Dispenser pump 1
V: 100ml
t: 30s
The dispensing process finishes once the
dispensing amount is reached by pressing
the 0/1 button, or stops automatically after
60 seconds. The duration t measured will be
shown in seconds and the amount drawn P
will be shown in ml/min.
Press the S "Save" button to save the
values.
M.-Nr. 06 533 430
-
e
A
e
A
P: 200,0ml/min
0/1
S
A
P: 200,0ml/min
0/1
S
A
It is also possible to go straight into
dispenser calibration. Switch the machine
on. Then press the multi-function dial in and
switch the machine on with the "Mains On"
switch.
Dispenser throughput (D1 to D13)
The throughput can be set for connected
dispensers in 1 ml/min increments from
0 ml/min to 999 ml/min.
Supervisor level ~ Settings
Dispensing throughput
Dispensing correction factor
After selecting "Dispenser throughput":
Settings ~ Dispensing throughput
Dispenser pump 1: 100,0 ml/min
Dispenser pump 2: 100,0 ml/min
Selection choice: - No
- 1 to 999,0 ml/min
Settings
-
e
A
e
A
31