Block Programmimg - Miele PW 6101 Programming Instructions Manual

Profitronic m innovation m
Table of Contents

Advertisement

Programming

Block programmimg

Block programming is used for specifying
the individual steps in the blocks. The blocks
for the individual areas are all identical and
contain the same basic parameters.
Programme block
Step
Block name
1. Block activation
2. Programme stop 1
3. Programme stop signal 1
4. Heating
5. Free temperature selection
6. Temperature
7. Hysteresis
8. Warm up
9. Water level 1
10. Water inlet 1
11. Dispensing method
12. Dispensing phase 1
13. Dispensing stop 1
14. Agitation from level
15. Water level stop 1
16. Wash time 1
17. Thermo stop
18. Water level 2
19. Water inlet 2
20. Dispensing phase 2
21. Dispensing stop 2
22. Water level stop 2
23. Wash time 2
24. Cool down
25. Wash time 3
26. Programme stop 2
27. Programme stop signal 2
28. Drain path 1
29. Drain level
30. Wash time 4
31. Drain path 2
32. Free spin speed selection
33. Spin
34. Repeat
35. Block end signal
X "locked" appears if the dispensing type
has been programmed to "No" in the
respective programme.
20
Standard settings
20 empty spaces
No
No
No
No
No
Cool air
Normal
X
0 mm / 0 l / 1:0 kg/l
Automatic
No
X
X
Automatic
No
No
X
0 mm
Automatic
X
X
No
No
No
No
No
No
No
0 mm
No
Drain
No
No
No
No
Block name
Block programming ~ Block parameter
Block name:
1. 1. Block activation: No
-
e
Enter a name for the block.
1. Block activation
At the start of programming each block a
decision needs to be made about the
activation status of the block.
Selection choice:
– No
The programme block is not carried out.
– Permanent
The programme block is a fixed part of the
programme structure and is always carried
out.
– Block+
The programme block is only carried out if
the + i "Block+" button is pressed.
e
S
A
M.-Nr. 06 533 430