Tray Linking Does Not Work - Lexmark CS510 User Manual

Hide thumbs Also See for CS510:
Table of Contents

Advertisement

Troubleshooting
Action
a
Check if the distance between the defects is equal to one of
the following:
25.1 mm (0.98 in.)
29.8 mm (1.17 in.)
43.9 mm (1.72 in.)
45.5 mm (1.79 in.)
94.2 mm (3.70 in.)
b
If the distance between the defects equals 25.1 mm (0.98 in.),
29.8 mm (1.17 in.), or 94.2 mm (3.70 in.), then replace the
photoconductor unit.
c
If the distance between the defects equals 43.9 mm (1.72 in.) or
45.5 mm (1.79 in.), then replace the developer unit.
Do the repeating defects still appear?

Tray linking does not work

Notes:
The trays can detect paper length.
The multipurpose feeder does not automatically detect the paper size. You must set the size from the
Paper Size/Type menu.
Action
Step 1
a
Open the trays, and then check if they contain paper of the
same size and type.
Check if the paper guides are in the correct positions for
the size of the paper loaded in each tray.
Check if the paper size indicators on the paper guides are
aligned with the paper size indicators on the tray.
b
Resend the print job.
Do the trays link correctly?
Yes
No
1
The problem is
Check if the
solved.
distance
between the
defects is equal
to one of the
following:
37.7 mm
(1.48 in.)
78.5 mm
(3.09 in.)
95 mm
(3.74 in.)
2
Take note of the
distance, and
then contact
customer
support
or your
service
representative.
Yes
No
The problem is
Go to step 2.
solved.
186

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs517Cs517deCs510dteCs510de6305027