Newport SMC100PP Manual page 10

Single-axis motion controller/driver for dc or stepper motor
Hide thumbs Also See for SMC100PP:
Table of Contents

Advertisement

SMC100CC & SMC100PP
EDH0312En1010 – 10/11
Single-Axis Motion Controller/Driver for DC or Stepper Motor
Invoke Node (from the .NET library provided by LabVIEW)
This dynamic VI allows to access to all commands of the selected instrument from the
CommandInterface DLL. The user can select one function from a list.
The command syntax is "AA". The command name is the beginning of the function
name. That allows the user to refer to the controller's manual to get the description of
the command to select.
Inputs
• reference is the refnum associated with the instrument object on which you want to
invoke a method or perform an action.
• error in describes LabVIEW error conditions that occur before this node runs.
• input 1..n are example input parameters of a method.
Outputs
• reference out returns reference unchanged.
• error out contains LabVIEW error information.
• return value is an example return value of a method.
• output 1..n are example output parameters of a method.
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smc100cc