In this example we will refer to the two Parani-SD1000s as SD1 and SD2 respectively. To use this
menu, please do the following:
Step 1. Connect SD1 and then push the START button.
Step 2. Disconnect SD1, connect SD2 and then push the Next but ton after setting up Slave
configuration. At this time, the dip switch value should be ATcmd mode. The flow control setting can
be changed only through dip switch.
Step 3. Disconnect SD2, once again connect SD1 and then push the Finish button. The pairing
configuration should be completed. Make sure that each Parani-SD1000' s connect LED is on. At this
point, when both Parani-SD1000' s restart the connection will be established automatically.

3.11 ParaniUpdater

Parani-SD1000 supports firmware updates. You can download new firmware images for the Parani-
SD1000 at http://www.sena.com. With the ParaniUpdater, you can update the firmware of Parani-
SD1000 by selecting the firmware image file and pushing Start button.
* Note: DO NOT power off Parani-SD1000 while the firmware update is progressing, this may damage
the Parani-SD1000.