Altronix ALTV244UL3 Installation Manual
Altronix ALTV244UL3 Installation Manual

Altronix ALTV244UL3 Installation Manual

Altv244ul3 series cctv power supplies
Hide thumbs Also See for ALTV244UL3:

Advertisement

ALTV244UL3 Series
CCTV Power Supplies

Installation Guide

Models Include:
• ALTV244UL3
- 24VAC @ 3.5 amp (85VA)
or 28VAC @ 3 amp (85VA).
- Four (4) Fuse Protected Outputs.
- Factory installed 3-wire line cord.
• ALTV244ULX3
- 24VAC @ 3.5 amp (85VA)
or 28VAC @ 3 amp (85VA).
- Four (4) Fuse Protected Outputs.
- Factory installed 3-wire line cord.
• ALTV244175UL3
- 24VAC @ 7 amp (175VA)
or 28VAC @ 6.25 amp (175VA).
- Four (4) Fuse Protected Outputs.
- Factory installed 3-wire line cord.
• ALTV244ULCB3
- 24VAC @ 3.5 amp (85VA)
or 28VAC @ 3 amp (85VA).
- Four (4) PTC Protected Outputs.
- Factory installed 3-wire line cord.
• ALTV244175ULCB3
- 24VAC @ 7 amp (175VA)
or 28VAC @ 6.25 amp (175VA).
- Four (4) PTC Protected Outputs.
- Factory installed 3-wire line cord.
Rev. 040406

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALTV244UL3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Altronix ALTV244UL3

  • Page 1: Installation Guide

    ALTV244UL3 Series CCTV Power Supplies Installation Guide Models Include: • ALTV244UL3 • ALTV244ULCB3 - 24VAC @ 3.5 amp (85VA) - 24VAC @ 3.5 amp (85VA) or 28VAC @ 3 amp (85VA). or 28VAC @ 3 amp (85VA). - Four (4) Fuse Protected Outputs.
  • Page 2: Specifications

    Overview: ALTV244UL3 Series CCTV Power Supplies provide 24VAC or 28VAC distributed via four (4) fuse or PTC protected outputs for powering CCTV Cameras, heaters and other video accessories. Four (4) Output ALTV244UL3 Reference Chart: Altronix Model Number 24VAC 3.5 amp 5 amp/ 3.5 amp/...
  • Page 3: Terminal Identification

    Keep power-limited (PTC protected outputs only) wiring separate from non power-limited wiring. Minimum 0.25” spacing must be provided. Use separate knockouts. 5. Set power switch on power distribution board marked [PD] to ON position for models ALTV244UL3, ALTV244ULX3 or ALTV244ULCB3 (Figs. 1-3, pgs. 4, 5).
  • Page 4 24VAC configuration Class 2 Not Wet/Class 3 Wet Fuse 28VAC configuration Class 1 non power- limited non-power limited Black Lead Black Lead XFMR Back Panel White Lead of Enclosure Green Lead (Ground) 115VAC Input 50/60 Hz. - 4 - ALTV244UL3 Series...
  • Page 5 AC Input and protected outputs must leave cabinet through separate knockouts. 0.25" spacing must be provided between AC Input and low voltage wiring. 115VAC 50/60Hz Input, For supply connection use wire rate for at least 90˚C. 0.9 amp ALTV244UL3 Series - 5 -...
  • Page 6 2 through 4) INPUT 24VAC configuration Class 2 Not Wet/Class 3 Wet non-power Illuminated Power Disconnect limited Circuit Breaker with manual reset Black Lead White Lead XFMR Green Lead (Ground) 115VAC Input 50/60 Hz. - 6 - ALTV244UL3 Series...
  • Page 7 3.5” (88.9mm) (88.9mm) 12” (304.8mm) 12” (304.8mm) 2.5” (63.5mm) 5.88” (149.35mm) 3.5” (88.9mm) 1.13” 1” (28.7mm) (25.4mm) 7.5” 4.5” 4.5” (190.5mm) (114.3mm) (114.3mm) 4.5” (114.3mm) 1” 1” (25.4mm) (25.4mm) 5.75” 0.88” 0.88” (146.05mm) (22.35mm) (22.35mm) ALTV244UL3 Series - 7 -...
  • Page 8 (25mm) (267mm) (25mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IIALTV244UL3Series J11M MEMBER - 8 - ALTV244UL3 Series...

This manual is also suitable for:

Altv244ulcb3Altv244ulx3Altv244175ulcb3Altv244175ul3

Table of Contents