3.2.2 Status
The upper right section shows the status of the transmitter and silence
detector. Status indicates the fault summary line status. Any �lashing
fault indicator on the front panel of the unit will cause the Green colored
"OK" block to turn Red with the word "FAULT" in it.
The Silence Sensor indicator will be Green and will indicate "OK" during
normal levels of program material. When program material ceases to be
present, this block will change to Yellow with the word "WARNING" in it,
then eventually change to Red with the word "FAULT" in it.
The action of this indicator re�lects a typical slow VU meter with timing
set by the design of the sensor. This design approach allows the user to
be able to set the timing of the alarm sensor with good accuracy. This
setting will be described later.