Dimplex VF5452L Owner's Manual page 7

6909410210; 6909410110; 6909680110
Hide thumbs Also See for VF5452L:
Table of Contents

Advertisement

Opti-V Installation
recommended dimensions
located in Figure 1.
!
NOTE: Dimensions provided
are minimum clearances and will
vary depending on type of support
framing and inishing options.
!
NOTE: Framing should be
constructed to support:
VF2927L / VFA2927 - 63 lbs (29 kg)
VF5452L - 116 lbs (52 kg)
2. Allow up to 4 ft. (121.9 cm) of
service cable for connecting
Figure 1
A
53.4 in
VF5452L
(1356 mm)
29.0 in
VF2927L
(736 mm)
29.0 in
VFA2927
(736 mm)
C
E
D
A
B
17.7 in
(450 mm)
17.7 in
(450 mm)
17.7 in
(450 mm)
a power supply wire to the
cable clamp on the Opti-V
when installing before inish-
ing wall.
!
NOTE:
alternating current (VAC) circuit
is recommended, but the unit is
constructed that it can operate
using voltages from 120-240VAC.
!
NOTE: Use minimum 14 AWG
supply cable with two insulated
copper conductors (white and
black) and one bare ground wire.
B
C
D
13.6 in
2.9 in
(345 mm)
(74 mm)
13.6 in
2.9 in
(345 mm)
(74 mm)
13.6 in
2.9 in
(345 mm)
(74 mm)
A 15 amp, 120 volt
G
E
F
5.3 in
18.6 in
(135 mm)
(474 mm)
5.3 in
18.6 in
(135 mm)
(474 mm)
5.3 in
18.6 in
(135 mm)
(474 mm)
F
G
55.3 in
(1404 mm)
29.9 in
(760 mm)
29.9 in
(760 mm)
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vf2927lVfa2927Opti-v vf5452lOpti-v vf2927lOpti-v vfa29276909410210 ... Show all

Table of Contents