EN: This product is only suitable for well insulated rooms or occasional use. DE: Dieses Produkt ist nur für gut isolierte Bereiche oder
gelegentliche Verwendung geeignet. FR: Ce produit convient uniquement à des endroits bien isolés ou pour un usage occasionnel.
IT: Questo prodotto è adatto solo per spazi ben isolati o per uso occasionale. ES: Este producto sólo es adecuado para espacios
bien aislados o un uso ocasional. NL: Dit product is uitsluitend geschikt voor goed geïsoleerde ruimten of voor sporadisch gebruik.
PL: Produkt ten jest odpowiedni wyłącznie do dobrze odizolowanych miejsc lub do okazjonalnego użytku. NO: Dette produktet egner
seg kun for godt isolerte rom eller sporadisk bruk. RO: Acest produs este adecvat exclusiv spaţiilor bine ventilate sau utilizării ocazionale.
CZ: Tento výrobek je vhodný pouze do dobře izolovaných prostor nebo k příležitostnému použití. DK: Dette produkt er kun egnet til
velisolerede rum eller lejlighedsvis brug. PT: Este produto somente é adequado para espaços bem isolados ou uso ocasional. SE: Denna
produkt är endast avsedd för välisolerade utrymmen eller tillfällig användning. FI: Tämä tuote soveltuu ainoastaan hyvin eristettyihin tiloihin
tai satunnaiseen käyttöön. SK: Tento výrobok je vhodný len pre dobre izolované priestory alebo na občasné použitie. SI: Ta izdelek je
primeren le za dobro izolirane prostore ali za občasno uporabo. HR: Ovaj proizvod je pogodan samo za dobro izolirane prostore ili
povremenu upotrebu. HU: Ez a termék csak jól szigetelt terekhez vagy eseti használatra alkalmas
This product complies with all the required Product Safety, Electromagnetic Compatibility and Environmental Standards.
This product is fully compliant with the LVD, EMC, RoHS and Eco Design Directives.
08/54578/0 ISSUE 6 OCN 11971

Advertisement

Table of Contents
loading

Summary of Contents for Dimplex Vivente VVT125

  • Page 1 OPERATING & INSTALLATION MANUAL Vivente Landscape Electric Fire Models: V VT7 5 , V VT100, VVT125 , VVT1 5 0 EN: This product is only suitable for well insulated rooms or occasional use. DE: Dieses Produkt ist nur für gut isolierte Bereiche oder gelegentliche Verwendung geeignet.
  • Page 3: Important Safety Advice

    CAUTION: Please read this information guide carefully to be able to safely install, use and maintain your product. Important Safety Advice When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electrical shock and injury to persons, including the following: If the appliance is damaged, check with the supplier before installation and operation.
  • Page 4: General Information

    Dimplex Vivente Electric Fire Models: VV T 75 , V V T1 0 0 , V V T 1 2 5 , V V T 1 5 0 Thank you for choosing a Dimplex electric fire. General Information CAUTION: Ensure installation does not allow fire to be in direct contact with building vapor barrier or insulation and meets all local building code.
  • Page 5: Installation Instructions

    Installation Instructions Step 1: Choosing Installation Type The Vivente can be configured in 4 different ways: • Single-sided – Front glass only (see Fig 1a) • Two-sided - Right (see Fig 1b) • Two-sided - Left (see Fig 1c) • Three-sided (see Fig 1d). The Vivente is supplied as a three-sided configuration.
  • Page 6: Step 3: Installing The Product

    Fitting panel – After Installation The Back Panel can also be change after the product has been installed, a suitably competent person is required to carry out this task. Please follow the steps below. 1. Disconnect product from Power Supply and remove front trim on unit. See Fig. 2 2.
  • Page 7: Step 4: Fuelbed Assembly

    The product must not bear the weight of the finished wall located above it. Consider the use of a lintel for appropriate support. 2.Using any combination of the three fixing methods (Fig. 13 a,b,c), fix the product to its supporting structure. 3.Build the finished wall up against the appliance using the glass trims as a guide.
  • Page 8: Operation And Use

    Operation and Use WARNING: Failure to follow these operating instructions may result in injury and/or damage. Thank you for choosing the Vivente. We hope you enjoy using your new electric fire. Please take a few minutes to read these instructions. This will help you understand and benefit from all of the following features: •...
  • Page 9 On this setting SmartSense will only switch the flame effect when it detects movement between the hours of 5-11pm, so if you enter the room during the day the fire will not react. However in the evening, your Dimplex fire will instantly switch on your flame effect – remembering your last setting.
  • Page 10 There are seven settings available on the onboard controls. (Display shows "AMB1" to "AMB7") "AMB8" is a customisable mood setting that is available via the Dimplex Flame Connect App. Please Note: "-F6-" is not an available setting when in "AMB6", "AMB7" or "AMB8".
  • Page 11: Remote Control

    Remote control The fireplace is supplied with a remote control. Operating Instructions using REMOTE CONTROL - See Figure 17 Icon Display Funtion Description Press Once to turn the product on. ("ON") Press a second time to put the product into standby. ("ST.BY" is shown, then "." is displayed "FIRE"...
  • Page 12: Product Features Overview

    CAUTION: No obvious symptoms Unfortunately, it is not obvious when a button or coin battery is stuck in a child’s oesophagus (food pipe). There are no specific symptoms associated with this. The child might: • cough, gag or drool a lot; •...
  • Page 13 Smart Phone App “Flame Connect” allows you to control your fire's function over Bluetooth, from your hand. Search for “Flame Connect” on your App Store and install to get started. Frequency band(s) this product operates in: 2.4GHz. Maximum radio-frequency power transmitted in the frequency band(s) this product operates in: 2.71dBm Fault Codes On Board Display Description...
  • Page 14: Maintenance

    The partially reflective glass should be completely dried with a lint free cloth to prevent water spots. To prevent scratching, do not use abrasive cleaners. CAUTION: Assembly, installation and repair of this heater must be carried out by Dimplex or its authorised agent.
  • Page 15 Fig. 1a Fig. 1b Fig. 1c Fig. 1d Fig. 2 Fig. 3a...
  • Page 16 Fig. 4 Fig. 3b Fig. 6 Fig. 5 Fig. 8 Fig. 7...
  • Page 17 Fig. 9 Fig. 10a Fig. 10b...
  • Page 18 Fig. 11 X + 30mm MODEL ‘X’ ‘X’ V V T7 5 764mm V V T1 0 0 1014mm V V T1 2 5 1260mm V V T1 5 0 1514mm 200 - 800...
  • Page 19 Fig. 12 Fig. 13a 150mm 200 - 800mm Fig. 13b Fig. 13c Fig. 14...
  • Page 20 Fig. 15 Fig. 16 Fig. 17...
  • Page 21 VVT75...
  • Page 22 VVT100...
  • Page 23 VVT125...
  • Page 24 VVT150...
  • Page 25 Fig. 18...
  • Page 28 Republic of Ireland Tel: 01 8428 222 www.dimplex.co.uk Dimplex Millbrook House, Grange Drive, Hedge End, Southampton, SO30 2DF © Glen Dimplex Heating and Ventilation. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission...