Checking The Earth Leakage Breaker - Ricoh pro c901 Troubleshooting Manual

Hide thumbs Also See for pro c901:
Table of Contents

Advertisement

Checking the Earth Leakage Breaker

This section explains how to check the earth leakage breaker.
• When this machine's circuit breaker is set to "Off", do not switch it to "On". Doing so could result
in electric shock, fire, smoke, or tripping of the room's breakers.
• If the earth leakage breakers are not functioning normally, contact your sales or service representative.
This machine has two earth leakage breakers.
For details about where they are located, see "Guide to Components", About This Machine.
Some options are equipped with earth leakage breakers.
Once a year, check that the earth leakage breakers function properly. Normally, the breakers are in the
On position.
Check both breakers in the same way.
1.
Press the operation switch to turn off the power.
2.
Turn off the main power.
3.
Using a ballpoint pen or similar pointed object, press in the earth leakage breaker's test
button.
CAL151
Checking the Earth Leakage Breaker
4
125