Condensate composition

The condensate volume and ingredients may change with regionally and
seasonally varying gas quality and air quality. Typically the following
ingredients and concentrations can be expected:
Substance
Ammonium
Lead
Cadmium
Chrome
Halogenated hydrocarbons
Hydrocarbons
Copper
Nickel
Mercury
Sulfate
Zinc
Tin
Vanadium
pH-value
Table 5 Typical condensate composition
Greenstar combi 100 p / 151 p
) heating
MS
Value in ppm (mg/l)
1.2
 0.01
 0.001
 0.005
 0.002
0.015
0.028
 0.1
 0.0001
1
 0.015
 0.01
 0.001
4.8
Greenstar combi 151 p, ZWB42-3A...
Unit
VAC
Hz
W
W
dB(A)
°F ( °C)
psi (bar)
°F ( °C)
32 - 122 (0 - 50)
gal (l)
lbs. (kg)
inch
17-21/64" × 33-15/32" × 13-57/64"
(mm)
4

Regulations

Observe all rules, regulations, standards and guidelines applicable to the
installation and operation of this appliance in your country.
Valves external to the boiler must be fitted with T-handles and
condensate piping must be installed in accordance with the State
Plumbing Code.
4.1

Compliance with standards and regulations

The installation must conform to the requirements of the authority
having jurisdiction or, in the absence of such requirements, to the latest
edition of the National Fuel Gas Code, ANSI Z223.1./NFPA 54. In
Canada, installation must be in accordance with the requirements of
CAN/CSA B149.1, Natural Gas and Propane Installation Code.
This wall-mounted condensing gas boiler complies in its design and
mode of operation with the American National Standard ANSI Z21.13/
CSA4.9, latest edition for Gas-Fired Low-Pressure Steam and Hot Water
Boilers.
Other confirmed approvals and certifications are indicated by labels on
the boiler.
If so advised by the responsible agency, the installation must satisfy the
requirements of the standard for Controls and Safety Devices for.
Automatically Fired Boilers, ANSI/ASME CSD-1.
Install CO detectors per local regulations. Wall-mounted gas condensing
boilers require yearly maintenance ( Chapter 14, page 48).
Regulations | 13
NG
LPG (propane)
120
120
60
60
205
205
< 6
< 6
45
45
187 (86)
187 (86)
30 (2.07)
30 (2.07)
32 - 122 (0 - 50)
0.925 (3.5)
0.925 (3.5)
110.2 (48)
110.2 (48)
(440 × 850 × 353)
6720872361 (2017/04)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenstar combi 151 pZwb42-3a seriesZwb28-3a series

Table of Contents