Mounting The Appliance - Bosch Greenstar combi 100 p Installation And Service Instructions For Contractors

Residential gas condensing boiler
Hide thumbs Also See for Greenstar combi 100 p:
Table of Contents

Advertisement

22 | Notes on installation and operation
5 1/8"
(130 mm)
10 15/64"
(260 mm)
=
Fig. 14 Hydraulics connection plate (top view)
▶ Determine pipe size for the gas supply.
▶ To fill and drain the system, install a fill and drain valve at the lowest
point.
6720872361 (2017/04)
=
6 720 641 933-14.1O
6.5

Mounting the appliance

NOTICE:
Residue, metal shavings, and contaminants in the piping can
damage the appliance.
▶ Flush the piping thoroughly and completely to remove all residue.
▶ Follow the instructions with respect to water quality (
Chapter 6.1.1, page 19).
▶ Remove packaging, observing all notes and symbols.
▶ On the type plate, check the identification of the target country and
suitability for the gas type supplied by the local gas utility company
( page 8).
Removing the cover
The cover is secured with two screws against unintentional removal
(electrical safety).
▶ Always keep the cover secured with these screws.
▶ Undo screws (step 1).
▶ Lift strap (step 2) and remove cover toward the front (step 3).
1
Fig. 15 Remove the cover
Hanging the appliance
▶ Check that the gas type matches ( data plate).
▶ Remove the transport brackets.
▶ Place the gaskets on the pipe connections.
▶ Hang the appliance.
▶ Check the positioning of the gaskets on the pipe connections.
▶ Tighten the union nuts on the pipe connections.
2
3
1
6 720 641 933-96.2O