3.9

Technical data

Input/Output
Max. input rate 180/79 °F (82/26 °C)
Max. output rate 104/86 °F (40/30 °C)
Max. output rate 122/86 °F (50/30 °C)
Max. output rate 176/140 °F (80/60 °C)
Output rate domestic hot water (DHW), 113 °F (45 °C)
Output rate domestic hot water (DHW), 140 °F (60 °C)
Min. input rate 180/79 °F (82/26 °C)
Min. output rate 104/86 °F (40/30 °C)
Min. output rate 122/86 °F (50/30 °C)
Min. output rate 176/140 °F (80/60 °C)
Gas connection value
Natural Gas – H
= 1,010 BTU/ft
s
Liquid Propane Gas – H
= 2,500 BTU/ft
D-S
Permissible inlet gas pressure
NG
LPG (propane)
DHW
Max. DHW flow rate
Nominal DHW flow rate (at 140 °F (60 °C) outlet temperature)
Outlet temperature
Max. cold water inlet temperature
Max. approved DHW pressure
Minimum water pressure
Flue gas
Flue gas mass flow at maximum/minimum nominal output
Flue gas temperature 176/140 °F (80/60 °C) at maximum/minimum nominal heat
input
Flue gas temperature 104/86 °F (40/30 °C) at maximum/minimum nominal heat input
CO
at max. nominal output
2
CO
at minimum nominal output
2
Condensate
Max. condensate quantity (t
= 86 °F (30 °C))
R
pH level, approx.
General
Voltage
Frequency
Max. power consumption (central heating mode)
Max. power consumption (Stand-by)
Sound pressure level
Max. supply temperature
Max. permissible operating pressure (P
Permissible ambient temperature
Nominal water capacity (heating)
Weight (without packaging)
Dimensions, W x H x D
Table 3 Technical data ZWB28-3A...
Greenstar combi 100 p / 151 p
3
3
(37.3MJ/m
)
3
3
(93.1MJ/m
)
) heating
MS
Greenstar combi 100 p, ZWB28-3A...
Unit
NG
BTU/hr (kW)
100,000 (29.3)
BTU/hr (kW)
93,800 (27.5)
BTU/hr (kW)
93,100 (27.3)
BTU/hr (kW)
89,400 (26.2)
BTU/hr (kW)
93,600 (27.4)
BTU/hr (kW)
91,400 (26.8)
BTU/hr (kW)
24,600 (7.2)
BTU/hr (kW)
23,900 (7.0)
BTU/hr (kW)
23,900 (7.0)
BTU/hr (kW)
21,800 (6.4)
3
3
BTU/ft
(MJ/m
)
99 (2.8)
3
3
BTU/ft
(MJ/m
)
in. W.C. (mbar) 3.5-10.5" (8.7-26.1)
in. W.C. (mbar)
gpm (l/min)
2.64 (10)
gpm (l/min)
2.03 (7.7)
°F ( °C)
104 - 140 (40 - 60) 104 - 140 (40 - 60)
°F ( °C)
140 (60)
psi (bar)
150 (10.3)
psi (bar)
4.35 (0.3)
g/s
12.0/3.2
°F ( °C)
147/133 (64/56)
°F ( °C)
117/90 (47/32)
%
9.4
%
8.6
gph (l/h)
0.6 (2.3)
4.8
VAC
120
Hz
60
W
205
W
< 6
39
dB(A)
°F ( °C)
187 (86)
psi (bar)
30 (2.07)
°F ( °C)
32 - 122 (0 - 50)
gal (l)
0.925 (3.5)
lbs. (kg)
110.2 (50)
inch
17-21/64" × 33-15/32" × 13-57/64"
(mm)
(440 × 850 × 353)
Product Description | 11
LPG (propane)
98,600 (28.9)
93,800 (27.5)
93,100 (27.3)
89,400 (26.2)
93,600 (27.4)
91,400 (26.8)
40,100 (11.7)
39,900 (11.7)
39,600 (11.6)
36,200 (10.6)
39 (1.1)
8-13" (19.9-32.3)
2.64 (10)
2.03 (7.7)
140 (60)
150 (10.3)
4.35 (0.3)
11.7/4.9
147/133 (64/56)
117/90 (47/32)
11.0
10.4
0.6 (2.3)
4.8
120
60
205
< 6
39
187 (86)
30 (2.07)
32 - 122 (0 - 50)
0.925 (3.5)
110.2 (50)