Condensate Composition; Regulations; Compliance With Standards And Regulations - Bosch Greenstar FS Series Installation And Maintenance Instructions For Contractors

Residential gas condensing boiler
Table of Contents

Advertisement

Regulations

Input / Output
Voltage
Frequency
Max. power consumption (central heating mode)
Max. power consumption (standby mode)
Sound pressure level
Max. supply temperature
Max. permissible operating pressure (P
Permissible ambient temperature
Nominal water capacity (heating)
Weight (without packaging)
Maximum overall dimensions W x H x D
Table 11
3.19

Condensate composition

The condensate volume and ingredients may change with regionally and
seasonally varying gas quality and air quality. Typically the following
ingredients and concentrations can be expected:
Substance
Value in ppm (mg/l)
Ammonium
Lead
≤ 0.01
Cadmium
≤ 0.001
Chrome
≤ 0.005
Halogenated
≤ 0.002
hydrocarbons
Hydrocarbons
Copper
Nickel
Mercury
≤ 0.0001
Sulphate
Zinc
≤ 0.015
Tin
≤ 0.01
Vanadium
≤ 0.001
pH value
Table 12 Typical condensate composition
26
) heating
MS
1.2
0.015
0.028
≤ 0.1
1
4.8
Unit
NG
Vac
120
Hz
60
W
205
W
<6
dB (A)
≤ 39
°F ( °C)
190 (88)
psi (bar)
30 (2.07)
°F ( °C)
32-122 (0-50)
Gall (L)
0.925 (3.5)
lbs (kg)
164 (74)
15
1
inch (mm)
21
/
x 41
16
557 x 1048 x 555
4
Regulations
Observe all rules, regulations, standards and guidelines applicable to the
installation and operation of this appliance in your country.
Valves external to the boiler must be fitted with T-handles and
condensate piping must be installed in accordance with the State
Plumbing Code.
4.1

Compliance with standards and regulations

The installation must conform to the requirements of the authority
having jurisdiction or, in the absence of such requirements, to the latest
edition of the National Fuel Gas Code, ANSI Z223.1./NFPA 54. In
Canada, installation must be in accordance with the requirements of
CAN/CSA B149.1, Natural Gas and Propane Installation Code.
This wall-mounted condensing gas boiler complies in its design and
mode of operation with the American National Standard ANSI Z21.13/
CSA4.9, latest edition for Gas-Fired Low-Pressure Steam and Hot Water
Boilers.
Other confirmed approvals and certifications are indicated by labels on
the boiler.
If so advised by the responsible agency, the installation must satisfy the
requirements of the standard for Controls and Safety Devices for.
Automatically Fired Boilers, ANSI/ASME CSD-1.
Install CO detectors per local regulations. Wall-mounted gas condensing
boilers require yearly maintenance ( Chapter 15, page 66).
Greenstar FS/Combi FS – 6 720 810 590 (2020/04)
LPG (Propane)
120
60
205
<6
≤ 39
190 (88)
30 (2.07)
32-122 (0-50)
0.925 (3.5)
164 (74)
7
15
1
/
x 21
/
21
/
x 41
/
x 21
4
8
16
4
557 x 1048 x 555
7
/
8