14.1.5 Burner servicing

DANGER:
Fire danger!
▶ The burner may be operated only while installed in a wall-mounted
gas condensing boiler.
▶ Remove burner lid (steps 1 - 4).
2
1
Fig. 71 Removing the burner cover
▶ Remove burner and clean its components.
Fig. 72 Burner
▶ Reinstall burner in reverse order, including a new gasket if necessary.
▶ Adjust the gas-air ratio ( page 46).
Greenstar combi 100 p / 151 p
4
3
6 720 641 933-95.1o
7 181 465 330-08.2R

14.1.6 Heat exchanger block inspection and cleaning

NOTICE:
Damage to the coating of the heat exchanger.
▶ Cleaning of the heat exchanger should not be necessary until five
years after the initial commissioning.
▶ Only use a Bosch cleaning blade and Bosch cleaning brush.
▶ Only clean heat exchanger in case if soiling is clearly visible.
▶ Remove the inspection cover ( page 8) and any sheet metal insert
below, if installed.
▶ Determine degree of soiling of the heat exchanger through visual
inspection.
If mechanical cleaning is required:
To clean of the heat exchanger, use Bosch burner gaskets, cleaning brush
kit and cleaning blade, all of which are available as spare parts.
▶ Remove the condensate trap (steps 1 and 2) and place a suitable
container underneath.
1
Fig. 73 Removing the condensate trap
Inspection and maintenance | 51
2
6 720 641 933-93.1o
6720872361 (2017/04)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenstar combi 151 pZwb42-3a seriesZwb28-3a series