Heatline SARGON 18S Installation, Servicing And User Instructions Manual page 37

Pre-mix condensing system boiler
Table of Contents

Advertisement

Fit the replacement motor in reverse order ensuring the correct polarity of the
electrical connections
Open the isolating valves on the fl ow and return connections, refi ll, vent and re-
pressurise the water system to 1.5bar ensuring the pump union joints are sound.
In case of pump body damage:
Remove the motor as described above.
Remove the expansion vessel pipe connection 8
by releasing the clip on the pump body.
Remove the pressure switch connection as detailed
in section 18.12.
Disconnect the pumps outlet fi tting.(fi gure 38)
Remove the fi xing screws on the pump and
hydraulic block, located at the bottom right of the boiler.
(fi gure 39)
Remove the pump body assembly.
Detach the pump body from the hydraulic block
by removing the clip.
Fit the replacement body in reverse order ensuring that the pump washers are fi tted
and the correct polarity of the electrical connections is maintained.
Open the isolating valves on the fl ow and return connections, refi ll, vent and
re-pressurise the system ensuring the pump union joints are sound.
18.7 Primary Heat Exchanger and Burner
Read the notes at the head of this section before commencing any work
on the appliance.
Disconnect the pipes from the heat exchanger.
Release the union connections on the pump and hydraulic block, retaining the washers
for re-assembly.
Remove the pump, heat-exchanger and heat-exchanger three-way valve connecting
pipes.
Remove the burner as detailed in (17.7)
Remove the screws from the brackets retaining the exchanger.
33
Figure 38
Figure 39