18.5 Printed Circuit Board (PCB)
•
Read the notes at the head of this section before commencing any work on the
appliance.
•
Remove interface cover by lifting the two latches. (fi gure 34)
•
Access the main PCB by opening the PCB cover.
•
NOTE the location of each plug before removing the electrical connections from
the PCB by releasing the clips and carefully pulling off the connectors.
•
Release the 4 screws securing the PCB to the control panel and lift out the PCB
•
Fit the replacement PCB in reverse order of removal, ensuring that the PCB electrical
connections are correctly located and fully pushed home.
18.6 Pump
•
Read the notes at the head of this section before commencing any work
on the appliance.
•
The order of removal is dependant on whether it is
the motor or body that has failed.
In case of motor failure:
•
Disconnect the screws connecting the pump head to the body, fi gure 35.
•
Pull off the pump head and disconnect the electrical connection from the cable
connection box of the pump, fi gure 36.
Figure 35
Figure 34
Figure 36