Figure 4
your boiler or Heatline stockist. Please note the terminal is suitable for a fl at or pitched roof and
only approved Heatline fl ue products can be used with this boiler. The connection of the vertical
fl ue system is similar to the Horizontal fl ue connection. The system is connected with screws to
the boiler and the vertical extension pipes and roof terminal are connected by clips.
8.5. The 80/80mm twin fl ue pipe system may be extended up to a maximum of 20m in any
combination of horizontal or vertical confi guration using additional spare components available
from your boiler supplier or Heatline stockist.
NOTE: When such a system is used it is necessary to have all joints accessible for inspection.
8.6. The anti-plume kit comprises of a 710mm horizontal section with elbow to connect the
1m vertical condensing tube, which has a horizontal or vertical terminal dependant on your
requirements. The maximum length of horizontal fl ue including the terminal but excluding the
initial elbow from the boiler and 1m vertical condensing tube is 4m.
NOTE: For each additional 90º elbow ( or
two 45º elbows) used the maximum fl ue
length must be reduced by 1.5 m.
WARNING !
ONLY A HEATLINE APPROVED FLUE IS TO
BE USED WITH THIS PRODUCT. FAILURE
TO COMPLY WITH THIS REQUIREMENT WILL
INVALIDATE YOUR GUARANTEE AND MAY
LEAD TO A DANGEROUS SITUATION.
11
Figure 5
8.3. The 60/100mm horizontal fl ue system
may be extended up to a maximum of
5.0m, excluding the initial 90° bend, using
additional spare components available
from the supplier of your boiler or Heatline
stockist. Please note only use approved
Heatline fl ue products with this boiler. (Flue
type : C13 - C33 - C43 - C53)
8.4. A vertical 60/100mm fl ue kit is also
available (fi gure 6), which can be extended
up to a maximum of 5.0m, excluding the
initial boiler connection, using additional
components available from the supplier of
Figure 6