Release the side panels by removing the screws on the upper and lower sides (fi gure
27). Remove the panels by swinging them out and lifting them up.
17.7 Swing the control panel down towards you exposing the gas valve and hydraulic circuits.
Undo the nut on top of the gas valve, fi gure 28, and release the pipe from the fan assembly.
(Be careful not to damage or dislodge the restrictor located in the gas valve outlet) Remove
the nuts from around the heat exchanger and after disconnecting the electrodes, fi gure 29,
pull the fan and burner assembly forward giving access to the fan connections. Release the
electrical leads and remove the burner/fan assembly. (Figure 30)
Figure 28
Figure 29
Ionisation
Ignition
Electrode
Electrode
Figure 27