Burner Orifi Ce Removal; Igniter And Flame Sensor Removal - L.B. White Foreman CI500 Owner's Manual And Instructions

Ductable dual fuel indirect-fired heater lp vapor withdrawal or natural gas
Table of Contents

Advertisement

Available languages

Available languages

8. To reinstall new switch, reverse the procedure.
Burner Orifi ce/Igniter/Flame sensor
1. Remove lock nut.
Locking Nut
2. Pull the burner chassis out.
3. Disconnect the igniter cable from the igniter.
4. Disconnect the fl ame sensor cable from the fl ame
sensor.
5. Note set point location of drawer assembly elbow
(set point #3).
Mounting
Screw
Flame
Sensor
Lead
6. Remove mounting screw using 6mm allen key.
7. Pull drawer assembly elbow out of combustion
head assembly
Burner Orifi ce Removal
1. Remove burner orifi ce by using the 13/16 socket
2. Make note of washer behind orifi ce when rein-
stalling new orifi ce. Washer must be installed.
Foreman Ductable Dual Fuel Indirect-Fired Heater
High Voltage
Lead
Owner's Manual • Foreman
Combustion
Mixing
Head
Plate
Orifi ce

Igniter and Flame Sensor Removal

1. Remove the igniter and fl ame sensor clamp screw.
2. Position new igniter to measure 4 inches from
clamp to the end of the terminal connection.
3. Flame sensor should measure 3 inches from
clamp to the end of the terminal connection.
3 in.
4 in.
23
Igniter
Flame Probe
Flame Probe
Igniter