Fan Housing Removal; Fan Wheel Replacement - L.B. White Foreman CI500 Owner's Manual And Instructions

Ductable dual fuel indirect-fired heater lp vapor withdrawal or natural gas
Table of Contents

Advertisement

Available languages

Available languages

4. Removed the four bolts using a 1/2 inch open ended
wrench.
■ Ensure motor and fan pulleys are properly aligned
when reinstalling.
■ Motor bearings are permanently lubricated.

Fan Housing Removal

1. Remove fan belt. See belt replacement procedure.
2. Remove fan motor. See fan motor section.
3. Locate and remove the four bolts at the base of the
fan housing. See below.
4. Locate and remove the eight sheet metal screws.
See drawing below.
5. Pull fan wheel housing out.
Foreman Ductable Dual Fuel Indirect-Fired Heater
Bolts
(2 per side)
Owner's Manual • Foreman

Fan Wheel Replacement

1. Remove the fan belt. See Belt Replacement
Procedures.
2. Remove the fan shaft pulley. See Fan and Motor
Pulleys Procedures.
3. Loosen all allen set screws on the fan shaft, including
the set screw on the fan wheel hub.
4. Pull the fan shaft through the fan wheel and bearing
mount brackets.
5. Lower the fan wheel to get access to the bearing
mount bracket nuts behind the fan housing side.
6. Remove fan housing ring screws.
7. Remove fan wheel.
NOTE: When installing new fan wheel, ensure the fan
wheel hub is on the same side as the motor pulley.
Screws
(4 per side)
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Foreman ci750

Table of Contents