Technical Specifications - Froling S1 Turbo Installation Instructions Manual

Fire wood boiler
Table of Contents

Advertisement

3

3.3 Technical specifications

Test report data -
Lambda Control
16
Name
Nominal heat output
Electrical connection
Power consumption at nominal load
Power consumption in slumber mode
Weight of boiler incl. insulation and control
Total boiler capacity (water)
Water pressure drop (ΔT = 10 / 20 K)
Minimum boiler return temperature
Maximum permitted operating temperature
Permitted operating pressure
Airborne sound level
Permitted fuel as per EN 14961
Fuel loading door dimensions (width / height)
Fuel loading chamber capacity
Combustion time
- Beech
1)
Combustion time
- Spruce
1)
1. Values specified for combustion time are guideline values at nominal load and will vary depending on water content (15-25%) and fill level
(80-100%)
Name
Testing institute
Test report no.
Date of issue
Boiler class as per EN 303-5:2012
Boiler efficiency
1. TÜV Austria Services GmbH, Geschäftsbereich Umweltschutz, Am Thalbach 15, A-4600 Thalheim/Wels
Test data - Emissions in [mg/MJ]
Carbon monoxide (CO)
Nitrogen oxide (NOx)
Organic hydrocarbons (OGC)
Dust
1. The pollutant concentration is specified as a mass based on the energy content of the fuel fed to the combustion system in mg/MJ
Test data - Emissions in [mg/m³]
Carbon monoxide (CO)
Nitrogen oxide (NOx)
Organic hydrocarbons (OGC)
Dust
1. Emissions values based on dry flue gas at standard temperature and pressure (0°C, 1013 mbar) with a volume content of oxygen of 13%
Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com
S1 Turbo 15
kW
15
230V / 50Hz / fused C13A
W
37
3
kg
455
l
90
mbar
3.5 / 0.5
°C
bar
dB(A)
Part 5: Firewood class A2 / D15 L50
mm
350 / 360
l
80
h
4.9 - 7.0
3.0 - 4.2
S1 Turbo 15
TÜV Austria
1)
13-UW/Wels-
EX-044/1
20/03/2013
5
%
92.5
(nominal load)
1)
mg/MJ
69
mg/MJ
80
mg/MJ
3
mg/MJ
8
(nominal load)
1)
mg/m³
102
mg/m³
118
mg/m³
5
mg/m³
11
Technology
Technical specifications
S1 Turbo 20
20
42
3
465
90
8.3 / 1.5
60
90
3
< 70
350 / 360
80
3.5 - 5.0
2.1 - 3.0
S1 Turbo 20
TÜV Austria
1)
13-UW/Wels-
EX-044/2
21/03/2013
5
92.0
51
88
3
10
75
129
5
15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S1 Turbo and is the answer not in the manual?

Table of Contents