322-8:LAMP
CIRCUIT
')-1
LAMP Cl RCU IT
A. Description
The SSL/ESL projector is designed with a 24V
AC
Quartz Halogen Lamp ELC 250 watt.
A 200
watt
EJ
L Lamp may also be used with some reduction in light output.
A
high/low
switch located in the lamp house allows the selection of either the normal 24V or the 22V
secondary from the transformer.
Note
SSL-OL projector is, however, designed with a 120V AC Line Voltage Quartz Halogen Lamp
EWG or EYK 300 watt, and does not have a high/low switch, nor the transformer.
B. Replacement and Alignment
1. Disconnect the AC power cord.
2. Remove the lamp house cover.
3. Remove the black heat shield cover.
CAUTION : The shield cover may be hot.
4. Push the lamp ejection lever to the left and the lamp will come out.
5. When replacing a lamp, be sure that it snaps into the lamp socket properly and that the
heat shield and lamp house cover are re-installed properly.
6. For the maximum, even illumination, it may be necessary to adjust the lamp position
to allow for slight variations in lamps. Turn the knurled nut for horizontal adjustment.
Note
In the event of the lamp socket replacement, and the knurled nut has been removed from the
pin, make sure of the correct direction of the knurled nut when re-mounting to the pin. (Fig.
#108)
Fig. #108
- 72 -

Hide quick links: