Ricoh DDP70 Maintenance Manual page 104

Standard finisher
Hide thumbs Also See for DDP70:
Table of Contents

Advertisement

[Adjustment Procedures]
1. When the Sub-tray Paper Exit Solenoid (SD2) is OFF, check whether the gap
between the Sub-tray Gate and the Guide Plate B is the value stated below:
Value: A = 2.9 to 3.9 mm.
2. When the Sub-tray Paper Exit Solenoid (SD2) is ON, check that the gap between
the solenoid plunger and the bracket stopper is the value stated below:
Value: B = 5 ± 0.5 mm.
A = 2.9 to 3.9 mm
Figure 6-50. Adjustment of the Sub-tray Gate
3. If the value is outside that of the standard stated, loosen the two Solenoid Installa-
tion ⊕ screws then operate and adjust the Solenoid.
SOLENOID INSTALLATION
Figure 6-51. Adjustment of the Sub-tray Gate
4. Tighten the Solenoid ⊕ screws.
[Assembling Procedures]
1. Reinstall the Rear Cover and the Top Cover by reversing the procedure above.
M M
L
0 0
SUB-TRAY GATE
B = 5±
0.5 mm
SCREWS
Disassembling, Assembling & Adjustment
SD2
SOLENOID
6-29

Advertisement