Section 1 Introduction; Installation, Pneumatic And Electrical Connections, And Initial Configuration; Scope Of Manual; Conventions Used In This Manual - Fisher FIELDBUE DVC6200 Instruction Manual

Sis digital valve controller
Table of Contents

Advertisement

Instruction Manual
D103557X012

Section 1 Introduction

Installation, Pneumatic and Electrical Connections,
and Initial Configuration
Refer to the
DVC6200 Series Quick Start Guide (D103556X012)
installation, connection, and initial configuration information. If a copy of this quick
start guide is needed scan or click the QR code at the right, contact your
Process Management sales

Scope of Manual

This instruction manual is a supplement to the
(D103601X012)
that ship with every instrument. This instruction manual includes product specifications, reference
materials, custom setup information, maintenance procedures, and replacement part details.
This instruction manual describes using the 475 Field Communicator to set up and calibrate the instrument. You can
also use Fisher ValveLink software to setup, calibrate, and diagnose the valve and instrument. For information on using
ValveLink software with the instrument refer to ValveLink software help or documentation.
Do not install, operate, or maintain a DVC6200 SIS digital valve controller without being fully trained and qualified in
valve, actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property damage,
it is important to carefully read, understand, and follow all of the contents of this manual, including all safety cautions
and warnings. If you have any questions about these instructions, contact your Emerson Process Management sales
office before proceeding.

Conventions Used in this Manual

Navigation paths and fast‐key sequences are included for procedures and parameters that can be accessed using the
Field Communicator.
For example, to access Device Setup:
Field Communicator
Configure > Guided Setup > Device Setup (2‐1‐1)
Refer to Appendix B for Field Communicator menu trees.

Description

DVC6200 SIS digital valve controllers (figure 1‐1) are HART communicating, microprocessor­based
current­to­pneumatic instruments. The DVC6200 SIS digital valve controller has three fundamental functions.
1. Modulate a pneumatic output to a valve actuator in response to a demand signal from a logic solver to move the
valve to a safe state.
2. Perform periodic tests on a valve assembly to exercise the mechanical components that are prone to sticking.
3. Continuously monitor the health of the valve and report alerts.
office, or visit our website at www.Fisher.com.
DVC6200 Series Quick Start Guide (D103556X012)
for DVC6200 SIS
Emerson
Introduction
April 2016
Scan or click
to access
field support
and
safety manual
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents