Advertisement

Quick Links

Instruction Manual
Form 5867
January 2015
VSX4 and VSX8 Series Controller

Table of Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Principle of Operation . . . . . . . . . . . . . . . . . . . . . . . . .5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Startup and Shutdown . . . . . . . . . . . . . . . . . . . . . . . . .8
Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Controller Spring Adjustment . . . . . . . . . . . . . . . . . . . .8
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Parts Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
!
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion
and/or fi re causing property damage and
personal injury or death.
Fisher
controller must be installed,
®
operated and maintained in accordance
with federal, state and local codes, rules
and regulations and Emerson Process
Management Regulator Technologies,
Inc. (Emerson™) instructions.
Only a qualifi ed person must install
or service the VSX4 and VSX8 Series
controller. If a leak develops or if the
controller continually vents gas, service
to the unit may be required. Failure
to correct trouble could result in a
hazardous condition.
Installation, operation and maintenance
procedures performed by unqualifi ed
personnel may result in improper
adjustment and unsafe operations which
may result in equipment damage or
personal injury.
WarNINg
www.fisherregulators.com
VSX4 and VSX8 Series
TyPE VSX4
Figure 1. VSX4 and VSX8 Series Controller
The VSX4 and VSX8 Series controller do
not activate in response to fi re, seismic
and lightning events.

Introduction

Scope of the Manual
This Instruction Manual provides installation,
adjustment, maintenance and parts ordering
information for the VSX4 and VSX8 Series controller.
Instructions for other equipment used with the
controller, such as pressure regulators, can be found
in separate instruction manuals.
TyPE VSX8

Advertisement

Table of Contents
loading

Summary of Contents for Fisher EMERSON VSX4 Series

  • Page 1: Table Of Contents

    TyPE VSX4 Fisher controller must be installed, ® operated and maintained in accordance with federal, state and local codes, rules Figure 1.
  • Page 2: Specifications

    VSX4 and VSX8 Series Specifications The Specifications section lists the specifications for the VSX4 and VSX8 Series controller. The following information is stamped on the nameplate of VSX4 and VSX8 Series: Type and Class, Maximum Outlet Pressure and Spring Range. Additional operating information is located on the Regulator nameplate. Available Configurations Operating Temperature (TS) Types VSX4L and VSX8L: Low-pressure...
  • Page 3 VSX4 and VSX8 Series VSX4L VSX4H VSX8L 6 bar 16 bar 1.5 bar 5.5 bar A Min, Min and Max installation B Max installation only PS 6 bar 6 bar PSD 6 bar Pressure range following umax PS 20 bar P 16 bar PSD 6 bar service condition...
  • Page 4 VSX4 and VSX8 Series Table 2B. Type VSX8L Combined Overpressure and Underpressure Shutoff (OPSO and UPSO) Spring Ranges for Type CS804 REGULATOR CONTROLLER Spring Range Under Pressure Over Pressure Spring Part Number Minimum Maximum Shut-off (UPSO) Shut-off (OPSO) and Color Type Set Range UPSO Set Range Over UPSO...
  • Page 5: Principle Of Operation

    VSX4 and VSX8 Series OVERPRESSURE SHUTOFF (OPSO) UNDERPRESSURE SHUTOFF (UPSO) ADJUSTING SCREW ADJUSTING SCREW UNDERPRESSURE SHUTOFF (UPSO) SPRING DIAPHRAGM OVERPRESSURE SHUTOFF (OPSO) SPRING CONTROL LINE PORT DOWNSTREAM SENSE BLOCKING SCREW RESET PIN RESET BUTTON VALVE PLUG M1141 VALVE PLUG SPRING INLET PRESSURE, P OUTLET PRESSURE, P ATMOSPHERIC PRESSURE, Pb...
  • Page 6: Installation

    VSX4 and VSX8 Series Table 5. Controller Standard Factory Settings CONTROLLER STANDARD SETTINGS REGULATOR SETPOINT, mbar / psig UPSO / Minimum OPSO / Maximum OPSO / Maximum (1)(2) < 35 / 0.51 x 0.5 x 2.0 x 2.0 + 10 mbar / 0.145 psig 35 / 0.51 <...
  • Page 7: Dimensions

    VSX4 and VSX8 Series SPRING REMOVAL SPRING REMOVAL CLEARANCE 80 / 3.1 CLEARANCE 80 / 3.1 Ø 118 / 4.6 Ø 118 / 4.6 146 / 5.8 146 / 5.8 28 / 1.1 28 / 1.1 RESET TRIP CLEARANCE: 25 / 1 RESET TRIP CLEARANCE: 20 / 0.8 REMOVAL CLEARANCE: 45 / 1.8 REMOVAL CLEARANCE: 35 / 1.4...
  • Page 8: Startup And Shutdown

    VSX4 and VSX8 Series • When assembling piping and flanges, do not apply • Reset the controller per the resetting procedure excessive force to the body, bolts, O-rings, flanges (refer to the Resetting Procedure section for detailed or fittings. All connections should be compatible resetting instructions).
  • Page 9: Maintenance

    VSX4 and VSX8 Series Manual Shut-off Procedure (Figure 6) Controller in Closed (Tripped) Position (Figure 12) Using a screwdriver, press the manual shut-off button (key 23) to manually trip the controller. When the controller is in the closed position, the travel indicator (key 27) is not visible and easily moved when Manual Reset Procedure (Figure 7) for pressed inward with a finger.
  • Page 10 VSX4 and VSX8 Series Manual Shut-Off Button Procedure For VSX4 and VSX8 Series DOWNSTREAM CONTROL LINE CONNECTION Figure 6. Controller Manual Shut-off Button (key 23) Figure 7. Controller Manual Bypass Figure 8. Controller Bypass with Screwdriver...
  • Page 11 VSX4 and VSX8 Series Figure 9. Relatching the Controller Mechanism Figure 10. Repositioning the Reset Button Figure 11. Controller in Open (Reset) Position Figure 12. Controller in Closed (Tripped) Position...
  • Page 12 VSX4 and VSX8 Series Systematic Maintenance is Recommended as Specified Below: Table 6. Flow Chart for Checking Shut-off Mechanism - CLOSE THE UPSTREAM VALVE - CLOSE THE DOWNSTREAM VALVE High-Pressure Shutoff Low-Pressure Shutoff Supply pressure through outlet purge valve. Open the purge valve. Check the value of the shut-off pressure and for any downstream leakage.
  • Page 13 VSX4 and VSX8 Series Table 7. Recommended Tools TOOL USAGE • Adjustment of Overpressure and Underpressure Shutoff (OPSO / UPSO) setting Flathead screwdriver • Resetting procedure • Removal and installation of the actuator screws (key 16, Figure 13) 10 mm / 0.394 in. Wrench •...
  • Page 14: Parts Ordering

    VSX4 and VSX8 Series Parts Ordering Controller that have been disassembled for repair corresponding with your local Sales Office regarding replacement parts or technical assistance. must be tested for proper operation before being returned to service. When ordering replacement parts, refer to the key The type number, pressure ranges, functional number of each needed part as found in the parts list.
  • Page 15 VSX4 and VSX8 Series TORqUE: 1 TO 3 N•m / TORqUE: 9 TO 26 IN-LBS 3 N•m / 27 IN-LBS TORqUE: 5.7 TO 6.2 N•m / 50 TO 55 IN-LBS TORqUE: 0.9 TO 1.4 N•m / 8 TO 12 IN-LBS TORqUE: 3.2 N•m / 28 IN-LBS...
  • Page 16 The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC, a business of Emerson Process Management.

This manual is also suitable for:

Emerson vsx8 series

Table of Contents