Using ABB IP Configuration Tool

ABB IP Configuration Tool detects all the NETA-21 remote monitoring tools in the network.
The tool can be downloaded separately from www.abb.com, but it also comes bundled
with ABB Control Builder Plus, the IEC 61131-3 programming environment for ABB PLCs
and drives.
Use the tool, for an example, when you no longer know the IP address of the NETA-21 or
when you do the initial set-up.
If you have the ABB Control Builder Plus 2.3.0 build 312 or newer installed, do as follows:
1. Launch the tool from Tools –> IP-Configuration.
2. Start the scanning process by clicking the Scan button:
If no devices are found, make sure that your firewall does not interfere with the
scanning process. Disable your firewall and try again.
All devices found during the scanning process are presented in a table where each
device is in a separate row. In addition to the IP addresses of the device you can also
see the MAC address, device name, serial number and device ID information.