Westermo RFI-219-T3G User Manual

Westermo RFI-219-T3G User Manual

Redfox industrial series
Hide thumbs Also See for RFI-219-T3G:

Advertisement

Quick Links

User Guide
6641-22310
RedFox Industrial
S E R I E S
WeOS
Industrial Routing Switch
www.westermo.com

Advertisement

Table of Contents
loading

Summary of Contents for Westermo RFI-219-T3G

  • Page 1 User Guide 6641-22310 RedFox Industrial S E R I E S WeOS Industrial Routing Switch www.westermo.com...
  • Page 2: Software Tools

    Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
  • Page 3: Before Installation

    Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged. If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support.
  • Page 4: Maintenance

    Note. Fibre Optic Handling Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the fibre will be disconnected from the unit the protective hood on the transmitter/ receiver must be connected. The protective hood must be kept on during transportation. The fibre optic cable must also be handle the same way.
  • Page 5: Agency Approvals And Standards Compliance

    Agency approvals and standards compliance Art.no Denomination Type Approval/compliance 3641-4000 RFI-219-T3G EN 50121-4, Railway applications – Electromagnetic compatibility – Emission and immunity of the signalling and 3641-4110 RFI-211-T3G telecommunications apparatus 3641-4200 RFI-215-F4G-T3G EN 55022, Information technology equipment – Radio 3641-4210 RFI-207-F4G-T3G disturbance characteristics –...
  • Page 6: Safety Control Drawing

    Safety control drawing Direction / Position Input / Output values description IO / Status + = 60 VDC max IO / Status – = 80 mA max IO / Digital in + = 60 VDC max IO / Digital in – = 2.9 mA max Direction / Position...
  • Page 7 Safety control drawing Position Direction* / description Input/output values In/out / TD+ In/out / TD– In/out / RD+ Per port: Not connected U = ± 1 V (4V/us) I = ± 20 mA Not connected Data rate: In/out / RD– 10/100 Mbit/s Not connected Not connected...
  • Page 8: Declaration Of Conformity

    Declaration of Conformity Westermo Teleindustri AB Declaration of conformity The manufacturer Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Herewith declares that the product(s) Type of product Models Industrial Ethernet Switch RFI-x19-T3G-y, RFI-x11-T3G-y, RFI-x15-F4G-T3G-y, RFI-x07-F4G-T3G-y, RFI-x19-F4G-T7G-y, RFI-x11-F4G-T7G-y, RFI-x19-F4G-T7G-F8-y is in conformity with the following EC directive(s).
  • Page 9: Type Tests And Environmental Conditions

    Type tests and environmental conditions Phenomena Test Description Test levels EN 61000-4-2 Enclosure contact ± 6 kV Enclosure air ± 8 kV RF field AM modulated IEC 61000-4-3 Enclosure 20 V/m 80% AM (1 kHz), 80 – 2700 MHz Fast transient EN 61000-4-4 Signal ports ±...
  • Page 10 Westermo Denomination Description article number 3 x 10/100/1000 Mbit/s, Ethernet TX, RJ-45 3641-4100 RFI-219-T3G 16 x 10/100 Mbit/s, Ethernet TX, RJ-45 3 x 10/100/1000 Mbit/s, Ethernet TX, RJ-45 3641-4110 RFI-211-T3G 8 x 10/100 Mbit/s, Ethernet TX, RJ-45 3 x 10/100/1000 Mbit/s, Ethernet TX, RJ-45...
  • Page 11: Specification

    Housing Description Depending on RedFox model, the size of the enclosure may vary. There are two sizes available, a two-slot housing and a three-slot housing. Regardless of RedFox model, the slot on the far left will always be occupied by the power and CPU interface.
  • Page 12: Power And Cpu

    The isolated power supply has redundant power inputs and allows for a wide operating voltage range (see interface specification). The digital IO-port can be used for monitoring the unit (see Westermo OS management guide). The CPU module holds several interfaces. Three RJ-45 connectors with support for Ethernet 1000BaseTX, a USB port for easy save/load of system configuration and a console port.
  • Page 13: Interface Specifications

    Rated voltage 20 to 48 VDC Operating voltage 16 to 60 VDC Rated current RFI-219-T3G 0.63 (0.79*) A @ 20 VDC 0.26 (0.33*) A @ 48 VDC RFI-211-T3G 0.43 (0.60*) A @ 20 VDC 0.19 (0.25*) A @ 48 VDC RFI-215-F4G-T3G 0.63 (0.82*) A @ 20 VDC...
  • Page 14: Connection To Console Port

    Connection to console port The console port can be used to connect to the CLI (Command Line Interface). The console connector is a micro USB cable that connects to a FTDI FT232R USB to serial converter internally. For drivers please see www. ftdichip.com and download the appropriate VCP driver.
  • Page 15 Electrical specification USB 2.0 host interface Data rate High speed 480mbit/s Circuit type SELV Maximum supply current 500 mA Isolation to All other except Console Connection USB receptacle connector type A Conductive housing IO / Relay output 30 W Connect resistance Isolation to All other Connection...
  • Page 16 Position Direction Description In/Out BI_DA+ In/Out BI_DA– In/Out BI_DB+ In/Out BI_DC+ In/Out BI_DC– In/Out BI_DB– In/Out BI_DD+ In/Out BI_DD– Shield In/Out Connected to PE Position Direction* Description VBUS In/Out D– In/Out Console Shield In/Out Connected to PE (see more information on page 13) 6641-22310...
  • Page 17: Power Connection

    Power connection 4-position Product marking Direction Description No. 1 +DC1 Input Supply voltage input DC1 No. 2 +DC2 Input Supply voltage input DC2 No. 3 -COM Input Common No. 4 -COM Input Common Lynx supports redundant power connection. The positive inputs are +DC1 and +DC2, the negative input for both supplies are –COM.
  • Page 18: Led Indicators Power/Cpu

    LED indicators Power/CPU Status Description Unit has no power. GREEN All OK, no alarm condition. Alarm condition, or until unit has started up. (Alarm conditions are configurable, see ''WeOS Management Guide''). BLINK Location indicator ("Here I am!"). Activated when connected to IPConfig Tool, or upon request from Web or CLI.
  • Page 19: Interface Modules

    Interface modules 8 copper ports All ports support category 5e cable or better and can handle cable lengths up to 150 m (492 ft). Interface specifications 8 copper ports Electrical specification IEEE std 802.3. 2005 Edition Data rate 10 Mbit/s or 100 Mbit/s, manual or auto Duplex Full or half, manual or auto Circuit type...
  • Page 20 LED indicators 8 copper ports Status Description Copper ports 1 – 8 No link. GREEN Link established. GREEN FLASH Data traffic indication. YELLOW Port alarm and no link. Or if FRNT, RSTP or Link Aggregation mode, port is blocked. Position Direction* Description In/Out...
  • Page 21 The F4G interface has four SFP slots supporting Ethernet 10/100/1000BaseFX/X. Each slot can hold one SFP transceiver for copper or fibre cable. For supported transceivers see SFP transceivers user guide (art no. 6100-0000) available at www. westermo.com. Interface specifications Optical/Electrical specification IEEE std 802.3.
  • Page 22: Led Status

    LED indicators F4G Status Description Fibre ports 1 – 4 No link. GREEN Link established. GREEN FLASH Data traffic indication. YELLOW Port alarm and no link. Or if FRNT, RSTP or Link Aggregation mode, port is blocked. Position Direction* Description Receive port Transmit port * Direction relative this unit.
  • Page 23 LED indicators F8 Status Description Fibre ports 1 – 8 No link. GREEN Link established. GREEN FLASH Data traffic indication. YELLOW Port alarm and no link. Or if FRNT, RSTP or Link Aggregation mode, port is blocked. Position Direction* Description Receive port Transmit port * Direction relative this unit.
  • Page 24 F4G-T4G, 4 SFP slots and 4 Gbit copper ports The F4G-T4G interface has four SFP slots supporting Ethernet BaseFX/X and four RJ-45 connectors supporting Ethernet 10/100/1000BaseTX/T. Each SFP slot can hold one SFP transceiver for copper or fibre cable. Fibre transceiver distances range from 550 m (0.34 mi) to 120 km (74,6 mi).
  • Page 25 LED indicators F4G-T4G Status Description Copper ports 1 – 4 No link. Fibre ports 5 – 8 GREEN Link established. GREEN FLASH Data traffic indication. YELLOW Port alarm and no link. Or if FRNT, RSTP or Link Aggregation mode, port is blocked. Position Direction* Description...
  • Page 26: Sfp Transceivers

    SFP Transceivers See SFP Transceivers User Guide 6100-0000 for supported SFP transceivers. Note: The unit supports Westermo labelled transceivers only. Deviations With copper transceiver 1100-0148 the specified operating temperature on the RFI-series is 0 to 50ºC. FRNT reconfiguration times can not be guaranteed with copper transceivers.
  • Page 27: Wall Mounting

    Snap on mounting, see figure. Note! For proper vibration and chock performance Westermo recommends standard top-hat DIN-rail TH 35-15 according to EN 60715. Removal Press down the support at the back of the unit using a screwdriver.
  • Page 28: Getting Started

    Getting Started This product runs Westermo Operating System (WeOS) which provides several management tools that can be used for configuration of the unit. • WeConfig WeConfig is a Network configuration management tool (NCM) made for commissioning and maintenance of components in a network.
  • Page 29: Referring Documents

    Referring documents Type Description Document number Management Guide Westermo OS management guide 6101-3201 Cable factory reset on RedFox Industrial It is possible to set the unit to factory default settings by using a standard (straight) Ethernet RJ-45 cable. 1. Power off the switch and disconnect all Ethernet cables (including copper and fibre).
  • Page 30 6641-22310...
  • Page 31 6641-22310...
  • Page 32: Sales Units

    Other Offices infos@westermo.fr sales@westermo.com.sg www.westermo.fr www.westermo.com Germany Sweden info@westermo.de info.sverige@westermo.se www.westermo.de www.westermo.se For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code REV. D 6641-22310 2015-03 Westermo Teleindustri AB, Sweden – A Beijer Electronics Group Company...

Table of Contents