Message Responses

The BW100 response to a flow rate (MT=50) load (MT=51) or speed (MT=52) message
request is in the following format.
som DEVICE MT READING eom
Example:
Data
Field
som
DEVICE
MT
READING
eom
The response to a material total (MT=53) message request is in the following format.
som DEVICE MT READING UNITS eom
Example:
Data
Field
som
DEVICE
MT
READING
UNITS
eom
7ML19985DJ01
Milltronics BW100 - INSTRUCTION MANUAL
ASCII
Example
Character
Description
STX
start of message
00
from BW100 # 0
50
material flow rate response
392.5
is 392.5
CR
end of message
ASCII
Example
Character
Description
STX
start of message
01
from BW100 # 1
53
material total response
129.2
is 129.2
t
metric tonnes
CR
end of message