To Access the PROGRAM Mode:
from the run mode

Master Reset

Prior to programming, balancing and calibration, a master reset of the BW100 should be
done.
Parameter P999
Refer to

Load Cell Balancing

If you are operating a two load cell belt scale, it is recommended that the load cells be
balanced electronically prior to initial programming and calibration, or after either or both
load cells have been reinstalled or replaced.
Note:
Unbalanced load cells adversely affect the performance of your belt
conveyor weighing system.
Load Cell
' A '
With the conveyor stopped and locked out, lift the belt off the weighing idlers.