Section 1. Important Safety Instructions

READ AND FOLLOW ALL INSTRUCTIONS
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
EQUIPMENT UNDER PRESSURE: Always turn pump off prior to installing or servicing the power pack or cell.
Your pump/filter system is operated under pressure and the pressure must be released before you begin work.
Please see your pump/filter owner's manual for further instructions.
To reduce the risk of electric shock, fire or injury, service should only be attempted by a qualified pool service professional.
Jandy® AquaPure® Ei chlorine generating devices are designed for domestic (residential) swimming pool use
only. Contrary use could affect performance, void warranty, and may result in property damage, serious injury, or
death.
• Operating a chlorine generator without water flowing through the cell may cause a build up of flammable
gases, resulting in fire or explosion.
• Keep equipment out of reach of children.
• A damaged supply cord should only be replaced by the manufacturer, service agent or electrician.
• When installing and using this electrical equipment, always follow basic safety precautions.
• Before performing installation, disconnect all power.
• Connect to a circuit that is protected by a ground fault circuit interrupter (GFCI).
• Do not install within an outer enclosure or beneath the skirt of a hot tub or spa.
Installation must be done in accordance with the National Electrical Code ("NEC" or NFPA-70) in the US, the Canadian
Electrical Code ("CEC" or C22.1) in Canada, and/or any other local and national installation codes.
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH. Connect only to a branch circuit that is
protected by a ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the circuit
is protected by a GFCI. Make sure such a GFCI should be provided by the installer and should be tested on a routine
basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should
be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump
without the test button being pushed, a ground current is flowing, indicating the possibility of electrical shock. Do not
use the device. Disconnect the device and have the problem corrected by a qualified service representative before
using.
A wire-binding screw for grounding (labeled ) is provide inside the power pack. To reduce risk of electric shock,
connect the ground wire to the grounding points in the power pack and of your electric service or supply panel with a
conductor equivalent in size to the circuit conductors supplying this equipment.
The power pack must be interlocked/interconnected with the pool pump motor power source to ensure that the
chlorinator only operates when the pool pump is operating.