MESSAGE TRANSMISSON
7.2.3

Operation mode

The operation mode of the inverter can be read from the network.
Virtual address
(byte boundary)
Address
(word boundary)
H100000C8
*
When accessing a message, the access size should be the size stated in the table above.
<Word block read (operation mode)>
Item
Request
Not applicable
Operation mode is returned.
Normal
response
Response
Error
response
66
Size
(word boundary)
100
1
Offset
+0
Offset
+0
Error code (Refer to page 61)
Applications
Description
Operation mode
Data Portion
Bit 15 to Bit 0
Operation mode
Bit 15 to Bit 0
Message
Access
Read Write
Operation mode
Value
PU operation
H0001
PUJOG operation
H0003
Network operation
H0004
×