INVERTER SETTING
Parameters whose functions are always the same
When the FR-A7NF is mounted to the inverter, following parameter functions are always the same.
(Changed setting is invalid even if the setting value is changed.)
Parameter
Number
79
Operation mode selection
180
RL terminal function selection
181
RM terminal function selection
182
RH terminal function selection
183
RT terminal function selection
184
AU terminal function selection
185
JOG terminal function selection
186
CS terminal function selection
187
MRS terminal function selection
188
STOP terminal function selection
189
RES terminal function selection
190
RUN terminal function selection
191
SU terminal function selection
192
IPF terminal function selection
193
OL terminal function selection
194
FU terminal function selection
195
ABC1 terminal function selection
196
ABC2 terminal function selection
Communication operation
338
command source
Communication speed command
339
source
22
Name
Setting
0
7
0
1
2
3
9999
9999
9999
24
9999
65
12
0
1
2
3
4
99
9999
0
0
Function
Network operation mode
*3
PU operation interlock
*4
Low-speed operation command
Middle-speed operation command
High-speed operation command
Second function selection
— (no function)
— (no function)
— (no function)
Output stop
— (no function)
PU/NET operation switchover
*3
PU operation interlock
*4
Inverter running
Up to frequency
Instantaneous power failure/undervoltage
Overload alarm
Output frequency detection
Fault output
— (no function)
Operation command source communication
Speed command source communication
Refer
to Page
25
25
— *2
— *2
— *2
— *2
— *2
— *2
— *2
— *2
— *2
— *2
— *2
— *2
— *2
— *2
— *2
— *2
— *2
— *2
30
30