Details Of Plug-In Mode - AE Techron LVC 5050 Quick Start Manual

Dual channel power supply amplifier
Table of Contents

Advertisement

Details of the Plug In Module
Pin
Function
1,2,
Available for additional features
3,4
Standby, When Pins 3 and 4 are shorted output section of
amplifier forced into standby.
5
Ground pin for use with pins 6, 7, and 8
6
Voltage monitor, will have 1/20th of voltage at output of
Channel 2. Pin 6 is inactive when amplifier is used in either
mono mode.
7
Current monitor, will have 1 volt for every 4 amps of current
at output of Channel 2, pin is inactive when amplifier is used
in either mono mode.
9-11
Balanced input for Channel 2. Pins 9 or 11 can be connected
to Pin 10 if an unbalanced input is desired. Pins 9 and 11 are
not active when amplifier is used in either mono mode.
12
Ground pin for use with pins 13, 14, and 15.
13
Voltage monitor, will have 1/20th of voltage at output of
Channel 1, when operated in 2 channel or Parallel Mono
mode and 1/40th of the voltage when operated in Bridged
Mono mode. Pin 13 is active in all modes of operation.
14
Current monitor, will have 1 volt for every 4 amps of current
at output of Channel 1, when operated in 2 channel or Bridge
Mono mode. When operated in Parallel Mono mode 1 volt for
every 6 amps of output current. Pin 14 is active in all modes
of operation.
16-18
Balanced input for Channel 1. Pins 16 or 18 can be connected
to Pin 17 if an unbalanced input is desired. Pins 16 and 18 are
active in all modes of operation.
Page 11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents