Sharp MD-X7H Service Manual page 57

Hide thumbs Also See for MD-X7H:
Table of Contents

Advertisement

• If the VOL UP/VOL DOWN button is pressed during setting indication, the setting increases/decreases, and the new setting is stored in RAM.
• If the VOL UP/VOL DOWN button is held down, the setting changes continuously with 100 ms cycle.
• If the REC button is pressed, the setting returns step by step excepting the following case.
A signal offset (HAO) → Offset tentative setting → RF side FG adjustment (RFG)
RF side TCRS adjustment (RCG) → RF side groove TG adjustment (GTG)
RF side groove TG adjustment (GTG) → Innermost periphery move → RF side pit section adjustment (PTG)
RF side pit TG adjustment (PTG) → RF side FG rough adjustment (RFg) → Laser lighting (LON)
Laser lighting (LON) → Offset "0" setting → A signal offset tentative measurement (HAo)
If the measurement value is within the OK range, "
6. MANUAL adjustment mode
High reflection disc
Step No.
Setting Method
Step 1
Testmode STOP state
Step 2
Press the CD PLAY button six times. MANUAL adjustment menu
Press once the MD PLAY button. Initial setting → Temperature measuring mode
Step 3
Step 4
Press once the CD PLAY button. Laser ON
Press once the CD PLAY button. Innermost periphery move → Tracking ATT (E signal) setting
Step 5
Step 6
Press once the CD PLAY button. Tracking ATT (F signal) setting
Step 7
Press once the CD PLAY button. Indication of tracking EFMIO measurement
Step 8
Press once the CD PLAY button. Focus ATT (A signal) setting
Step 9
Press once the CD PLAY button. Focus ATT (B signal) setting
• If the MD STOP button is pressed while the MANUAL adjustment menu is displayed, the state is changed to the TEST mode STOP
state.
• If the REC button is pressed, the setting returns step.
Low reflection disc
Step No.
Setting Method
Step 1
Testmode STOP state
Step 2
Press the CD PLAY button six times. MANUAL adjustment menu
Press once the MD PLAY button. Initial setting → Temperature measuring mode
Step 3
Step 4
Press once the CD PLAY button. Laser ON
Press once the CD PLAY button. Innermost periphery move → Tracking ATT (E signal) setting
Step 5
Step 6
Press once the CD PLAY button. Tracking ATT (F signal) setting
Step 7
Press once the CD PLAY button. Indication of tracking EFMIO measurement (pit section)
Step 8
Press once the CD PLAY button. Focus ATT (A signal) setting
Step 9
Press once the CD PLAY button. Focus ATT (B signal) setting
Press once the CD PLAY button. Outside periphery move → Track closs setting
Step 10
Step 11
Press once the CD PLAY button. Tracking ATT (E signal) setting
Step 12
Press once the CD PLAY button. Tracking ATT (F signal) setting
Step 13
Press once the CD PLAY button. Indication of tracking EFMIO measurement (groove section)
Step 14
Press once the CD PLAY button. Focus ATT (A signal) setting
Step 15
Press once the CD PLAY button. Focus ATT (B signal) setting
• If the MD STOP button is pressed while the MANUAL adjustment menu is displayed, the state is changed to the TEST mode STOP
state.
• If the REC button is pressed, the setting returns step by step excepting the following case.
Track closs ATT setting (GTG) → Innermost periphery move → Focus ATT (B signal) setting (LBg)
7. EEPROM setting mode
a) Focus setting
Step No.
Setting Method
Step 1
Testmode STOP state
Step 2
Press the CD PLAY button seventimes. EEPROM setting menu
Step 3
Press once the MD PLAY button. Focus setting menu
Step 4
Press once the MD PLAY button. Focus system loop filter gain constant setting
Step 5
Press once the CD PLAY button. Focus system loop filter f characteristic constant 1 setting
Step 6
Press once the CD PLAY button. Focus system loop filter f characteristic constant 2 setting
Step 7
Press once the CD PLAY button. FZC oscillation histerisis level setting a
Step 8
Press once the CD PLAY button. Comparison level setting (normal) in case of FOK generation
" appears on the 8th character.
Remarks
Remarks
Remarks
– 21 –
MD-X8H
Display
[ t s m
e
]
[ _ M N U _ A J S T _ ]
[ T M P : _
_ _ _ ]
[ L O N : _ _ _ _ _ _ ]
[ P E G :
]
[ P F G :
]
[ P M I :
_ _ _ ]
[ H A G :
]
[ H B G :
]
Display
[ t s m
e
]
[ _ M N U _ A J S T _ ]
[ T M P : _
_ _ _ ]
[ L O N : _ _ _ _ _ _ ]
[ P E G :
]
[ P F G :
]
[ P M I :
_ _ _ ]
[ L A g :
]
[ L B g :
]
[ G C G :
]
[ G E G :
]
[ P F G :
]
[ G M I :
_ _ _ ]
[ L A G :
]
[ L B G :
]
Display
[ t s m
e
]
[E E P R O M _ S E T]
[ _ _ F o c u s _ _ _ ]
[ F G _ _ _ _ _ _
]
[ F F 1 _ _ _ _ _
]
[ F F 2 _ _ _ _ _
]
[ F Z H L E V _ _
]
[ F O K L E V n _
]