Sharp MD-X7H Service Manual page 118

Hide thumbs Also See for MD-X7H:
Table of Contents

Advertisement

MD-X8H
IC901 RH-iX2679AFZZ:System Control Micon(iX2679AF) (2/3)
Pin No.
Terminal Name
33
TRAY SW-A
34
TRAY SW-B
35
TRAY SW-C
36
TRAY SW-D
37
38
MAIN CLK
39
MAIN CLK
40
41*
Not used
42
Not used
43
RESET
44
RX IN
45
Power failure
detection
46
NAME IN
47
DATA IN/OUT
48
CLK IN/OUT
49
PROTECT
50
DSTB
51
52
53
KEY0
54
KEY1
55
KEY2
56
KEY3
57
Spare
58
Initial setting
59
SPAN selection
60
VSM
61
62
SD
63
Illumination ON/ P131
OFF switching
64
Not used
65
232C-IN
66
232C-OUT
67
V. LOAD
68
M-DATA
69
K-DATA
70
DSCK
71
MIC detection
72
RWC
73
SQOUT
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
Port Name
Input/Output
P124
Input
P125
Input
P126
Input
P127
Input
VDD
X2
X1
Input
VSS
XT2
XT1
Input
RESET
Input
INTP0
Input
INTP1
Input
INTP2
Input
INTP3
Input/Output
INTP4
Input/Output
INTP5
Input
INTP6
Input
AVDD
AVREFO
Input
AN10
Input
AN11
Input
AN12
Input
AN13
Input
AN14
Input
AN15
Input
P16
Input
AN17
Input
AVSS
P130
Input
Output
AVREF1
Input
RXD2
Input
TXD2
Output
P72
Output
SI1
Input
SO1
Output
SCK1
Output
P23
Input
P24
Output
SI0
Input
Main tray OPEN completion detection switch input
H: OPEN completion state when SW is OFF.
L: Other state when SW is ON. This switch provides the CLOSE function
when the tray lid is pressed.
Main tray CLOSE completion detection switch input
L: CLOSE completion state when SW is ON
H: Other state when SW is OFF
Sub-tray placing completion detection switch input
L: Placing completion state when SW is ON
H: Other state when SW is OFF.
Sub-tray SET completion detection switch input
H: SET completion state when SW is OFF
L: Other state when SW is ON.
To be connected to ADD
16 MHz crystal
16 MHz crystal
Ground potential To be connected to VSS
SUB CLK not used To be opened
SUB CLK not used To be connected to VSS
Reset input
Remote controller input
Power failure detection input Power failure = L
TEXT input from external MD
Data input/output from and to keyboard
Clock input/output from and to keyboard
Power amplifier stage abnormality detection input Abnormal state = 1
Strobe input from MD microcomputer Interruption input
A/D converter analog power To be connected to VDD
A/D converter reference voltage input Wiring separately from VDD
A/D input of key - 0
A/D input of key - 1
A/D input of key - 2
A/D input of key - 3
To be connected to VSS
Destination setting with A/D value
Tuner span selection
Input of electric field intensity in RDS ASPM state by using A/D value
A/D converter ground potential To be connected to VSS
SD input in case of TUNER AUTO SCAN
Illumination in ON state: H output
Illumination in OFF state: L output
D/A converter reference voltage input To be connected to VDD
Serial data input in UART mode
Data operation from external personal computer through PC card
Serial data output in UART mode
Data sending from external personal computer through PC card
Selection of 7.5V/5V line voltage supplied to MD
H is set to set the 7.5V line only when MD is set to LOAD or EJECT mode.
Serial data input from MD microcomputer
Serial data output to MD microcomputer
Serial clock output to MD microcomputer
MIC jack insertion detection input
READ/WRITE control output to CD DSP element
Serial input of sub-code data Q from CD DSP
– 82 –
Function
L: MIC connected, H: Not connected

Advertisement

Table of Contents
loading

This manual is also suitable for:

Md-x8hS0779mdx8h

Table of Contents