SECTION 3
Preparing for Communications
Reference:
List of Commands
Designation
Parameter designation
Parameter confirmation ::END
Comment
Parameter output
RESET
Tag Name List
Classification
Protocol
SECS
Operation
CIDRW System
64
User's Manual
Command input
(Tag name) = (Set value) <CRLF> Specify the parameter value corresponding to the tag name.
# (Comment) <CRLF> or CRLF
::GET_PARAM
::GET_SEG
::GET_E99SYS
::GET_VER
::EXIT
Parameter
Tag name
Baud Rate
S_BAUD
Device ID
S_DEVID
Time-out between
S_T1
characters
Protocol time-out
S_T2
Response time-out
S_T3
Time-out between
S_T4
blocks
Retry limit
S_RTY
Master/slave
S_MS
Double block detec-
S_DB
tion yes/no
Source ID
S_SRC
Single block No.
S_BNO
Baud rate for com-
C_BAUD
munications with
Amplifier Unit/Link
Unit
Number of Heads
C_HEAD
count processing
Checks the parameter designations that have been received so
far and, if there is no error, confirms the settings.
This is ignored as the comment line.
Outputs the set parameters (protocol, SECS, operation).
Outputs the set parameters (ID Tag memory map).
Outputs the set parameters (operations).
Outputs the set parameters (software revision).
Restarts the CIDRW Controller.
Setting range
1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200 bps
0 to 32767
0.1 to 10 s
0.2 to 25 s
1 to 120 s
1 to 120 s
0 to 31
M: Master
S: Slave
1: The header of the block currently being received
is compared with the correct block received
immediately before, and double blocks are
detected.
0: Double block detection is not performed.
0 to 32767
0, 1
9600, 19200, 38400 bps
Use a consistent baud rate setting within the same
system configuration.
0 to 31
0:
The number of Heads is automatically
detected at the start. Any increase or
decrease in the number of Heads is auto-
matically detected.
1 to 31: The number of Heads is specified. The
number of Heads detected is compared
with this specified number of Heads. If the
number of Heads changes, for example
because a Head fails, an error (with alarm)
is detected.
If a Head is not connected or an error is
detected with a connected Head, so that
the number of Heads does not match the
specified number, an error (with alarm) is
detected.
Explanation
Default setting
9600 bps
0
0.5 s
10 s
45 s
45 s
3
M
0
0
1
9600 bps
0

Advertisement