SECTION 6
Appendix

Regular Inspection

In order to maintain optimum performance of the functions of the CIDRW system, daily and periodic
inspections are necessary.
Inspection item
Supply voltage fluctuation
Environment
Ambient tem-
perature
Ambient
humidity
Vibration and
shock
Dust
Corrosive gas
I/O power
Voltage fluctu-
supply
ation
Ripple
Mounting condition
CIDRW System
160
User's Manual
Detail
Check that the supply voltage fluctuation
at the power supply terminal block is
within the permissible range.
Check that there are no frequent instan-
taneous power failures or radical voltage
drops.
Check that the ambient temperature and
humidity are within specified range.
Check that no vibration or shock is trans-
mitted from any machines.
Check that the system is free of dust
accumulation.
Check that no metal part of the system is
discolored or corroded.
Check on the I/O terminal block that the
voltage fluctuation and ripple are within
the permissible ranges.
Check that each device is securely
mounted.
Check that each connector is securely
connected.
Check that no wire is broken or nearly
broken.
Check if grounding to 100 Ω or less has
been done.
Criteria
To be within supply voltage rating.
To be within permissible voltage fluctua-
tion range.
To be within the specified range.
To be none.
To be within the specified range.
There must be no loose screws.
Each connector must be locked or
securely tightened with screws.
There must be no wire that is broken or
nearly broken.
To be grounded to 100 Ω or less.
Tools required
Multimeter
Power supply
analyzer
Maximum and
minimum ther-
mometer
Hygrometer
Multimeter
Oscilloscope