Omron V700-L11 User Manual page 59

V640 series cidrw system
Hide thumbs Also See for V700-L11:
Table of Contents

Advertisement

1.
Specify the parameters to be changed.
When the first parameter is specified, the ALARMS indicator flashes.
2.
Confirm the parameter change.
The input parameter is checked and written.
 Check for Correct Setting
The currently set data can be output so that you can check if it is correct.
1.
Send the parameter output command "::GET_E99SYS"
from the host device.
The carrier ID settings are displayed.
Do not change operation parameters other than RT, CIDOF,
and CIDLN.
This can cause the system to stop operating correctly.
For the V700-L22-V2, the "NVASC" parameter is added
to the end.
Change Data Segment Area
The data segment area (memory map) must be changed to communicate with ID Tags (RI-TRP-DR2B,
made by Texas Instruments). The procedure for changing the data segment area is explained here.
ID Tag Memory Maps
The commands, and the parameters that can be set, are indicated below.
Refer to page 159.
Preparing for Communications
CIDOF=00
CIDLN=16
::END
_
::GET_E99SYS
RT=10.0
CT=0.1
RTY=3
DINST=
MENT=
MODEL=L22
HREV=001.04
CIDOF=00
CIDLN=16
::END
_
V700-L22 Operation Example
RT=10.0
CT=0.1
RTY=3
DINST=
MENT=
MODEL=L22V2
HREV=001.00
CIDOF=00
CIDLN=16
NVASC=NOM
::END
V700-L22-V2 Operation Example
CIDRW System
SECTION 3
57
User's Manual