Pin No.
Signal name
1
—
2
Receive data
3
Send data
4
—
5
Signal ground
6
—
7
Request send
8
Send enabled
9
—
Recommended model
Cable
Connector
Socket
Hood
• Wiring for Connection to a CIDRW Controller
The cable length should be no greater than 15 m.
Link Unit
V700-L11
D-SUB, 9-pin, female
Socket type #4-40
Name
Pin No.
NC
1
RD
2
SD
3
NC
4
SG
5
NC
6
RS
7
CS
8
NC
9
Symbol
Signal direction
NC
—
Not connected
RD
Input
SD
Output
NC
—
Not connected
SG
—
NC
—
Not connected
RS
Output
Always ON during normal operation
CS
Input
NC
—
Not connected
Manufacturer
Hitachi Cable
OMRON
Ground shielded wires at the CIDRW Controller side.
Installation and Connections/Wiring
Remarks
Model
CO-MA-VV-SB 5PX28AWG
XM2D-0901
XM2S-0913
CIDRW Controller
V700-L22
D-SUB, 9-pin, female
Socket type #4-40
Pin No.
Name
1
NC
2
RD
3
SD
4
NC
5
SG
6
NC
7
RS
8
CS
9
NC
SECTION 2
CIDRW System
47
User's Manual