18.7

Three Service 50Hz Connection

Wiring for export models with three service breakers. The jumper wiring
is shown below.
Three Service Jumper
Wiring
Wire
From
1
J53
2
J59
3
J37
4
J45
5
J42
BREAKER TERMINAL
CONNECTIONS
L1 = Heater/Blower/Lighting
L2 = Pump 1/Circ/Ozone
L3 = Pump 2/CLEARRAY/Stereo
To
J51
J41
J36
J3
J4
1
J37
3
J44
J35
980™ Series
5
4
J65
J59
2
THREE
SERVICE
L3
BRN
D
L1 BRN
C
B
N1 BLU
A
L2 BRN
GRN
TB1