Export 50Hz Power Options - Sundance Spas Camden Owner's Manual

780 series
Table of Contents

Advertisement

tUS/Canada Certa/Chelsee/Hamilton 2-Pump Models (60Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
* In 40A configuration, the heater will not operate while either jets pump
is running in high speed. Note: pump 2 runs only in high speed.
** In 50A configuration, the heater will not operate while both jets pumps
are running in high speed. Note: pump 2 runs only in high speed. This
is the factory setting.
*** in 60A configuration, the heater will operate while both jets pumps are
running in high speed. Note: pump 2 runs only in high speed.

5.2 Export 50Hz Power Options

Export 1-Pump Camden/Metro Models (50Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
* In the 20A configuration, the heater will not operate at the same time as
the high speed jets pump. This is the factory setting.
** In the 30A configuration, the heater will operate at the same time as the
high speed jets pump.
Export 2-Pump Certa/Chelsee/Hamilton Models (50Hz)
Voltage:
# of Wires:
Frequency:
Current Draw:
Circuit Breaker:
* In 20A configuration, the heater will not operate while either jets pump is
running in high speed. This is the factory setting. Note: pump 2 runs
only in high speed.
** In 30A configuration, the heater will not operate while both jets pumps
are running in high speed. Note: pump 2 runs only in high speed.
*** In 40A configuration, the heater will operate while both jets pump are run-
ning in high speed. Note: pump 2 runs only in high speed.
240V/40A*
240 VAC
3
60Hz
26A
40A, 2-Pole
230V/20A*
230 VAC
3
50Hz
15A
20A
230V/20A*
230 VAC
3
50Hz
15A
20A
240V/50A**
240 VAC
3
60Hz
36A
50A, 2-Pole
230V/30A**
230 VAC
3
50Hz
21A
30A
230V/30A**
230 VAC
3
50Hz
23A
30A
240V/60A***
240 VAC
3
60Hz
45A
60A, 2-Pole
230V/40A***
230 VAC
3
50Hz
29A
40A
Page 11