Technical Data; Acs 611; Ambient Temperature; Electromagnetic Compatibility - Bosch ACS 611 Original Instructions Manual

A/c service-unit
Table of Contents

Advertisement

13. Technical data

13.1

ACS 611

Property
Dimensions H x W x D
Weight
Operating voltage
Frequency
Workplace emission sound pressure level
as per EN ISO 11204
Refrigerant
Low-pressure gauge
High-pressure gauge
Capacity of internal refrigerant cylinder
Safety class
Power output
13.2

Ambient temperature

Property
Storage and transport
Operation
13.3

Electromagnetic compatibility

This product complies with the standards EN 61000-6-2
and EN 61000-6-4.
Robert Bosch GmbH

14. Glossary

R
PS2 stick:
Storage medium with PS2 connection; used in order
to perform software update of ACS 611, or to store
Value/range
data from the internal memory of ACS 611 for data
1270 x 690 x 660 mm
management on a PC.
110 kg
R
Recovery phase:
230 VAC ± 10 %
The refrigerant is removed from the vehicle air
50/60 Hz
conditioner using suction, cleaned and routed into
< 70 dB(A)
the internal vessel of the ACS 611. The refrigerant oil
collected in the process is drained into the used oil
R134a
bottle at the ACS 611.
-1 bar – 16 bar ± 1 %
R
Vacuum phase:
-1 bar – 40 bar ± 1%
27 l
A vacuum is generated in the vehicle air conditioning
IP 20
system. Measurement of the drop in pressure
800 W
commences as soon as the vacuum has been
generated.
R
Fresh oil refill phase:
Fresh oil is added to the vehicle air conditioner.
Value/range
R
UV dye refill phase:
-25 °C – 60 °C
A certain quantity of UV dye is added to the vehicle
-13 °F – 140 °F
air conditioner.
10 °C – 45 °C
R
Filling phase:
50 °F – 113 °F
A certain quantity of refrigerant is added to the
vehicle air conditioner.
R
Total oil quantity:
This is the quantity of oil which has to be added
to the air conditioner according to the vehicle
manufacturer. The oil recovered from the air-
conditioning system is not taken into account.
i
The total oil quantity can be set in either automatic
or manual mode. If no compressor oil has to be
added to the air conditioner, the value for the total
oil quantity in the service parameters is "0 ml".
R
Added oil quantity:
This is the quantity of oil previously recovered
from the air conditioning system plus the added oil
quantity entered.
i
The added oil quantity can only be set in automatic
mode.
If the value is "0 ml", the quantity of compressor
oil added to the compressor corresponds to the
quantity of the recovered oil.
If the value for the added oil quantity is "20 ml", the
quantity of compressor oil added to the compressor
corresponds to the quantity of recovered oil plus
20 ml.
Technical data | ACS 611 | 59
S P00 D00 002
en
|
2013-04-10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents