Processing - Bosch ACS 611 Original Instructions Manual

A/c service-unit
Table of Contents

Advertisement

en
50 | ACS 611 | Operating instructions
<Automatic> button
!
Observe the ACS 611 menu prompting.
1. Call up start screen.
2. Press <Automatic>.
SELECT PORTS?
1 HP & LP PORTS
2 HP PORT
3 LP PORT
3. Select <1>,<2> or <3>; confirm with E.
SET VACUUM TIME
4. Set duration of vacuum generation with <0 – 9>,
z v and confirm with E.
CHARGING UV DYE?
1 - YES
2 - NO
5. Select <1> or <2>; confirm with E.
CHARGING OIL?
1 - YES
2 - NO
i
With <1> the following is shown:
INTRODUCE EXTRA OIL
The added fresh oil quantity (added oil quantity,
see glossary) must be set with <0 – 9>, z v and
confirmed with E.
6. Select <1> or <2> and confirm with E.
SET REFRIGERANT CHARGE
7. Enter refrigerant quantity (R134a) with <0 – 9>,
z v and confirm with E.
"
ACS 611 performs "Automatic service".
i
Return with <Stop>.
|
S P00 D00 002
2013-04-10
is displayed.
is displayed.
7.5

Processing

!
Observe the ACS 611 menu prompting.
1. Call up start screen.
2. Press <MENU>.
3. Select <Processing> with o u and confirm with E.
i
The processing duration is limited to 60 minutes
and stops automatically after the internal circuit has
been drained.
i
Return with <Stop>.
Robert Bosch GmbH

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents