Canceling A Configuration Change - Hirschmann Power MICE Reference Manual

Web-based interface industrial ethernet (gigabit) switch
Hide thumbs Also See for Power MICE:
Table of Contents

Advertisement

Basic Settings
Status
Meaning
notPresent
No ACA present.
ok
The configuration data from the ACA and the device
are consistent.
removed
The ACA has been removed after booting.
notInSync
The configuration data from the ACA and the device
are not consistent.
outOfMemory The local configuration data is too extensive to be
stored on the ACA.
wrongMa-
The configuration data in the ACA originates from a
chine
different device type and cannot be read or converted.
checksumErr The configuration data is damaged.
Table 3: ACA status

2.6.6 Canceling a configuration change

Operation
If the function is activated and the connection to the device is interrupted
for longer than the time specified in the field "Period to undo while con-
nection is lost [s]", the device then loads the last configuration saved.
Activate the function before you configure the device so that after an
incorrect configuration has interrupted your connection to the device,
you will be connected to the device again.
Enter the "Period to undo while the connection is lost [s]" in seconds.
Possible values: 10-600 seconds.
Default setting: 600 seconds.
Note: Deactivate the function after you have successfully saved the con-
figuration. You thus prevent the device from reloading the configuration
after the time period entered has elapsed, when you close the web inter-
face.
RM Web L3P
Release 4.1 03/08
2.6 Load/Save
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mach 4000

Table of Contents