1 GENERAL PRECAUTIONS

1.1.

Safety Precautions

1. Before servicing, unplug the power cord to prevent electrical shock hazard.
2. When replacing parts, use only manufacture's recommended components for safety.
3. Check the condition of power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the wire dressing, insulation barriers, insulation papers, shields, etc.
5. Before returning the serviced equipment to the customer, perform the following electrical tests to prevent shock hazard.
1.2.

For Service Technicians

ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help to prevent recurring malfunctions.
1. Cover the plastic parts with aluminum foil.
2. Ground the soldering irons.
3. Use a conductive mat on the worktable.
4. Do not grasp IC or LSI pins with bare fingers.
1.3.

About Lead Free Solder (PbF: Pb free)

Note
• In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder
that contains lead.
• We will use PbF when discussing the lead free solder used in our manufacturing process which is made from Tin (Sn),
Silver (Ag), and Copper (Cu).
• This model, and others like it, manufactured using lead free solder will have PbF stamped on the PCB. For service and
repair work we suggest using the same type of solder.
Distinction of PbF PCB
• PCBs (manufactured) using lead free solder will have a PbF stamp on the PCB.
Caution
• PbF solder has a melting point that is 50 ° - 70 °F, (30 ° - 40 °C) higher than Pb solder.
Please use a soldering iron with temperature control and adjust it to 700 ° ± 20 °F (370 ° ± 10 °C).
• Exercise care while using higher temperature soldering irons.: Do not heat the PCB for too long time in order to
prevent solder splash or damage to the PCB.
• PbF solder will tend to splash if it is heated much higher than its melting point, approximately 1100 °F, (600 °C).
• When applying PbF solder to double layered boards, please check the component side for excess solder which may
flow onto the opposite side (See figure below)
1.3.1.
Suggested Pb free solder
We recommend you to use the following solder when re-soldering components for repair. Before using other Pb free solder than the
following solder, make sure to confirm that the solder maker (you use) has the license agreement for Pb free solder.
Supplier: Senju Metal Industry Co., Ltd. (http://www.senju-m.co.jp)
Part Description in Senju: EcoSolder RMA02 P3 M705 Series
3