2. VCO Adjustment (PD-117 board)

Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin 8 of CN5502 (XHD OUT)
Measuring Instrument
Frequency counter
Adjustment Page
7
Adjustment Address
E5, E6
Specified Value
f = 15625 ± 30Hz
Note: Refer to "LCD type check" for the discrimination of the LCD type.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 7, address: E5, change the data and set the XHD
OUT frequency (f) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 7, address: E5, read the data, and this data is named
D
.
E5
5)
Convert D
to decimal notation, and obtain D
E5
5-4-1. Hexadecimal-decimal Conversion Table.)
6)
Calculate D
' using following equations (Decimal calculation),
E6
convert it to a hexadecimal number, and input to address: E6.
LCD TYPE S:
When D
'
20
E5
D
' = D
E6
E5
When D
' < 20
E5
D
' = 00
E6
LCD TYPE C:
When D
'
22
E5
D
' = D
E6
E5
When D
' < 22
E5
D
' = 00
E6
7)
Press the PAUSE button.
8)
Select page: 0, address: 01, and set data: 00.
'. (Refer to Table
E5
' – 20
' – 22

3. RGB AMP Adjustment (PD-117 board)

Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: Press the DISPLAY button and erase the screen indictors on the
LCD screen.
Note2: Refer to "LCD type check" for the discrimination of the LCD
type.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 7, address: E8, change the data and set the voltage
(A) between the reversed waveform pedestal and non-reversed
waveform pedestal to the specified value.
(The data of address: E8 should be "00" to "3F".)
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
A
Pedestal
5-31
Camera
Arbitrary
Pin 3 of CN5502 (VG)
External trigger :
Pin 4 of CN5502 (PANEL COM)
Oscilloscope
7
E8
LCD TYPE S: A = 3.63 ± 0.05V
LCD TYPE C: A = 3.00 ± 0.05V
Pedestal
2H