Danfoss VLT FC 100 Service Manual page 16

Vlt fc series d-frame hvac drive
Hide thumbs Also See for VLT FC 100:
Table of Contents

Advertisement

Introduction
1
1
FC 102, FC 202, and FC 103
High/Normal Load*
Typical Shaft output at 400 V [kW]
Typical Shaft output at 460 V [hp]
Typical Shaft Output at 480 V [kW]
Enclosure IP21
Enclosure IP54
Output current
Continuous (at 400 V) [A]
Intermittent (60 s overload) (at 400 V) [A]
Continuous (at 460/500 V) [A]
Intermittent (60 s overload) (at 460/500 V)
[kVA]
Continuous kVA (at 400 V) [kVA]
Continuous kVA (at 460 V) [kVA]
Max. input current
Continuous (at 400 V) [A]
Continuous (at 460/500 V) [A]
Max. cable size: line power, motor, brake
and load share [mm
Max. external electrical fuses [A]
Estimated power loss at 400 V [W]
Estimated power loss at 460 V [W]
Weight, enclosure IP21, IP54 kg (lbs)
Weight, enclosure IP20 kg (lbs)
4)
Efficiency
Output frequency
*Normal overload = 110% current for 60 s
Table 1.12 Line Power Supply 3x380–480 V AC
1) For type of fuse, see the Instruction Manual.
2) American Wire Gauge
3) Measured using 16.5 ft [5 m] shielded motor cables at rated load and rated frequency.
4) The typical power loss is at nominal load conditions and within ± 15% (depending on various voltage and cable
conditions).
5) Field wiring terminals on FC 102 N132, N160, and N315 models are not intended to receive conductors one size
larger.
Values are based on a typical motor efficiency (eff2/eff3 border line). Motors with lower efficiency add to the
power loss in the adjustable frequency drive and those with higher efficiency decrease it.
The losses are based on the default switching frequency. The losses increase significantly at higher switching
frequencies. LCP and typical control card power consumption values are included. Further options and customer
load may add up to 30 W to the losses. (Though typically, only 4 W extra for a fully loaded control card, or options
for slot A or slot B, each).
14
Service Manual
N110
NO
110
150
132
D1h
D1h
D3h
212
233
190
209
147
151
204
183
2
] (AWG
2)
)
5)
1)
315
4)
2555
2257
Danfoss A/S © Rev. 2014-02-10 All rights reserved.
N132
N160
NO
NO
132
160
200
250
160
200
D1h
D1h
D1h
D1h
D3h
D3h
260
315
286
347
240
302
264
332
180
218
191
241
251
304
231
291
2x95
(2x3/0)
350
400
2949
3764
2719
3622
62 (135)
62 (135)
0.98
0–800 Hz
N200
N250
N315
NO
NO
200
250
300
350
250
315
D2h
D2h
D2h
D2h
D2h
D2h
D4h
D4h
D4h
395
480
435
528
361
443
397
487
274
333
288
353
381
381
463
463
348
348
427
427
2x185
(2x350)
550
630
4109
5129
6663
3561
4558
5703
125 (275)
125 (275)
0–600 Hz
MG94A222
NO
315
450
355
588
647
535
588
407
426
567
516
800