5.3.9 TR-069 Settings
Default Value
PERIODIC_INFORM_INTERVAL
Value Format
Description
Value Range
Default Value
PERIODIC_INFORM_TIME
Value Format
Description
Value Range
Default Value
CON_REQ_USER_ID
Value Format
Description
Value Range
192
Administrator Guide
N
INTEGER
Specifies the interval length, in seconds, when the CPE must attempt
to connect with the ACS and call the Inform method.
Note
This setting is available only when
"PERIODIC_INFORM_ENABLE" is set to "Y".
30–2419200
86400
STRING
Specifies the time (UTC) to determine when the CPE will initiate the
periodic Inform method calls.
Note
Each Inform call must occur at this reference time plus or
minus an integer multiple of the
"PERIODIC_INFORM_INTERVAL". This
"PERIODIC_INFORM_TIME" parameter is used only to set the
"phase" of the periodic Informs. The actual value can be
arbitrarily set far into the past or future.
For example, if "PERIODIC_INFORM_INTERVAL" is set to
86400 (one day) and if "PERIODIC_INFORM_TIME" is set to
midnight on a certain day, then periodic Informs will occur
every day at midnight, starting from the set date.
If the time is set to "unknown time", the start time depends on
the CPE's settings. However, the
"PERIODIC_INFORM_INTERVAL" must still be adhered to.
If absolute time is not available to the CPE, its periodic Inform
behavior must be the same as if the
"PERIODIC_INFORM_TIME" parameter was set to the
"unknown time".
Time zones other than UTC are not supported.
4–32 characters
date and time format
0001-01-01T00:00:00Z
STRING
Specifies the user name used to authenticate an ACS making a
Connection Request to the CPE.
Max. 256 characters
Document Version 2016-05