Appendix: Technical data
Nominal power rating
Power supply
On-site fuse
Illumination
Degree of protection
Protection class
Continuous sound pressure level
(Lpa)
Ambient temperature
Maximum humidity
Installation surface / water spray The device must be placed and levelled on
(3
A-evaluated sound pressure level Lpa (slow) and Lpa (impulses) at operating personnel workplace is under 70 dB(A) in any
working mode.
90
3.4–3.8 kW
220–240 V
50/60 Hz (1/N/PE)
1 x 16 A
LED class 1
IP X0
<70 dB(A)
(3
+5 °C to maximum +35 °C
(empty the water system in case of frost).
80 % relative humidity without condensation.
Do not use device outdoors.
a horizontal, sturdy, water-resistant, and
heatproof base.
The device must not be cleaned using a water
jet. The device must be installed where it is
protected against water spray. The device must
not be located on a surface that is sprayed or
cleaned with a water hose, steam jets, steam
cleaner, or similar devices.
6.0–7.0 kW
380–415 V
50/60 Hz (3/N/PE)
3 x 16 A
User Manual WMF 9000 S +